ASTM B0280-23 - Standard Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service

Standard Specification for Seamless Copper Tube for Air Conditioning and Refrigeration Field Service

Format
Availability
Price and currency
English PDF Redline
Immediate download
72.23 EUR
English PDF
Immediate download
60.67 EUR
English Hardcopy
In stock
60.67 EUR
Standard number:ASTM B0280-23
Released:01.10.2023
Status:Active
Pages:9
Section:02.01
Keywords:air conditioning tube; field service tube; refrigeration tube; seamless copper tube; UNS No. C10200; UNS No. C12000; UNS No. C12200;
DESCRIPTION

1.1 This specification covers the requirements for seamless copper tube intended for use in the connection, repairs, or alternations of air conditioning or refrigeration units in the field.

Note 1: Fittings used for soldered or brazed connections in air conditioning and refrigeration systems are described in ASME Standard B16.22.

Note 2: The assembly of copper tubular systems by soldering is described in Practice B828.

Note 3: Solders for joining copper tubular systems are described in Specification B32. The requirements for acceptable fluxes for these systems are described in Specification B813.

1.2 The tube shall be produced from the following coppers, and the manufacturer has the option to supply any one of them, unless otherwise specified:

Copper
UNS No.

Previously Used
Designation

Description

 

 

 

C10200

OF

Oxygen free without
  residual deoxidants

C12000

DLP

Phosphorus deoxidized,
 low residual phosphorus

C12200

DHP

Phosphorus deoxidized,
 high residual phosphorus

1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.4 The following hazard statement pertains only to the test method described in 18.2.4 of this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.