ASTM B0395_B0395M-18 - Standard Specification for U-Bend Seamless Copper and Copper Alloy Heat Exchanger and Condenser Tubes
Standard Specification for U-Bend Seamless Copper and Copper Alloy Heat Exchanger and Condenser Tubes
Standard number: | ASTM B0395_B0395M-18 |
Released: | 01.03.2018 |
Status: | Active |
Pages: | 12 |
Section: | 02.01 |
Keywords: | condenser tube; copper; copper alloy; dual-gage; evaporator; heat exchanger; U-bend tube; C10200; C10300; C10800; C12000; C12200; C14200; C19200; C23000; C44300; C44400; C44500; C60800; C68700; C70400; C70600; C70620; C71000; C71500; C71520; C72200; |
1.1 This specification2 establishes the requirements for condenser, evaporator, and heat exchanger U-bend tubes that are manufactured from seamless copper and copper alloy tube.
1.2 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, SI units are shown in brackets. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.3 This specification is applicable to product 2 in. [50 mm] or less, inclusive, in diameter.
1.4 The product shall be produced from one of the following coppers or copper alloys, as specified in the ordering information:
Copper or | Previously Used | Type of Metal |
|
|
|
C10200 | OFA | oxygen-free without residual deoxidants |
C10300 | ... | oxygen-free, extra low phosphorus |
C10800 | ... | oxygen-free, low phosphorus |
C12000 | DLPA | phosphorized, low residual phosphorus |
C12200 | DHPA | phosphorized, high residual phosphorus |
C14200 | DPAA | phosphorized, arsenical |
C19200 | ... | phosphorized, 1 % iron |
C23000 | ... | red brass |
C44300 | Type B | admiralty metal |
C44400 | Type C | admiralty metal |
C44500 | Type D | admiralty metal |
C60800 | ... | aluminum bronze |
C68700 | Type B | aluminum brass |
C70400 | ... | 95-5 copper-nickel |
C70600 | ... | 90-10 copper-nickel |
C70620 | ... | 90-10 copper-nickel- |
C71000 | ... | 80-20 copper-nickel |
C71500 | ... | 70-30 copper-nickel |
C71520 | ... | 70-30 copper-nickel- |
C72200 | ... | copper-nickel |
1.5 The following safety hazard caveat pertains only to the test methods described in this specification.
1.5.1 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. (Warning—Mercury has been designated by many regulatory agencies as a hazardous substance that can cause serious medical issues. Mercury, or its vapor, has been demonstrated to be hazardous to health and corrosive to materials. Caution should be taken when handling mercury and mercury containing products. See the applicable product Safety Data Sheet (SDS) for additional information. Users should be aware that selling mercury and/or mercury containing products into your state or country may be prohibited by law.)
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.