PRICES include / exclude VAT
Homepage>ASTM Standards>ASTM C1189-11R18 - Standard Guide to Procedures for Calibrating Automatic Pedestrian SNM Monitors
Sponsored link
Released: 01.11.2018

ASTM C1189-11R18 - Standard Guide to Procedures for Calibrating Automatic Pedestrian SNM Monitors

Standard Guide to Procedures for Calibrating Automatic Pedestrian SNM Monitors

Format
Availability
Price and currency
English PDF
Immediate download
60.67 EUR
English Hardcopy
In stock
60.67 EUR
Standard number:ASTM C1189-11R18
Released:01.11.2018
Status:Active
Pages:9
Section:12.01
Keywords:gamma radiation; material control and accountability; neutron radiation; nuclear materials management; radiation detectors; radiation monitors; safeguards; security;
DESCRIPTION

1.1 This guide covers calibrating the energy response of the radiation detectors and setting the discriminator and alarm thresholds used in automatic pedestrian special nuclear material (SNM) monitors.

1.2 Automatic pedestrian SNM Monitors and their application are described in Guide C1112, which suggests that the monitors be calibrated and tested when installed and that, thereafter, the calibration should be checked and the monitor tested with SNM at three-month intervals.

1.3 Dependable operation of SNM monitors rests, in part, on an effective program to test, calibrate, and maintain them. The procedures and methods described in this guide may help both to achieve dependable operation and obtain timely warning of misoperation.

1.4 This guide can be used in conjunction with other ASTM standards. Fig. 1 illustrates the relationship between calibration and other procedures described in standard guides, and it also shows how the guides relate to an SNM monitor user. The guides below the user in the figure deal with routine procedures for operational monitors. Note that Guide C993 is an in-plant performance evaluation that is used to verify acceptable detection of SNM after a monitor is calibrated. The guides shown above the user in Fig. 1 give information on applying SNM monitors (C1112) and on evaluating SNM monitors (C1169) to provide comparative information on monitor performance.

FIG. 1 The Relationship of Calibration to Other Procedures Described in Standard Guides for SNM Monitors

 The Relationship of Calibration to Other Procedures
 Described in Standard Guides for SNM Monitors The Relationship of Calibration to Other Procedures
 Described in Standard Guides for SNM Monitors

1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.