ASTM C1497-24 - Standard Specification for Cellulosic Fiber Stabilized Thermal Insulation
Standard Specification for Cellulosic Fiber Stabilized Thermal Insulation
Standard number: | ASTM C1497-24 |
Released: | 15.07.2024 |
Status: | Active |
Pages: | 6 |
Section: | 04.06 |
Keywords: | cellulose; R-value; shrinkage; stabilized cellulose; thermal insulation; |
1.1 This specification covers the composition and physical properties of spray-applied cellulosic fiber stabilized thermal insulation applied to open or closed ceiling spaces, regardless of slope, where temperatures range from –49 to 194°F (–45 to 90°C).
1.2 Stabilized cellulosic fiber thermal insulation is produced by the addition of adhesive(s) to loose-fill cellulosic fiber insulation. The adhesive(s) are either added to the insulation at time of manufacture and, if necessary, activated by the addition of water when installed or the adhesive(s) are otherwise added to the insulation at the time of installation.
1.3 This is a material specification that is not intended to deal with methods of application that are supplied by the manufacturer.
1.4 The values stated in inch-pound units are to be regarded as standard. The SI units given in parentheses are for information only.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.