ASTM C1856_C1856M-24 - Standard Practice for Fabricating and Testing Specimens of Ultra-High Performance Concrete
Standard Practice for Fabricating and Testing Specimens of Ultra-High Performance Concrete
Standard number: | ASTM C1856_C1856M-24 |
Released: | 01.12.2024 |
Status: | Active |
Pages: | 5 |
Section: | 04.02 |
Keywords: | fresh concrete; hardened concrete; specimen fabrication; testing; ultra-high performance concrete; |
1.1 This practice covers procedures for fabricating and testing specimens in the laboratory and the field using a representative sample of ultra-high performance concrete (UHPC), for the purpose of determining the properties of the material. This practice is applicable to UHPC with a specified compressive strength of at least 120 MPa (17 000 psi), with nominal maximum size aggregate of less than 5 mm [1/4 in.] and a flow between 200 mm and 250 mm [8 and 10 in.] as measured by the modified flow table test described in Section 6.
1.2 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system are not necessarily exact equivalents; therefore, to ensure conformance with the standard, each system shall be used independently of the other, and values from the two systems shall not be combined.
1.3 If required results obtained from another standard are not reported in the same system of units as used by this standard, it is permitted to convert those results using the conversion factors found in the SI Quick Reference Guide (1).2
1.4 The text of this standard refers to notes and footnotes that provide explanatory material. These notes and footnotes (excluding those in tables and figures) shall not be considered as requirements of this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. [Warning—Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to exposed skin and tissue upon prolonged exposure.3 Hand protection should be worn when handling UHPC.]
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.