ASTM D2340-23 - Standard Test Method for Peroxides in Styrene Monomer
Standard Test Method for Peroxides in Styrene Monomer
Standard number: | ASTM D2340-23 |
Released: | 01.01.2023 |
Status: | Active |
Pages: | 3 |
Section: | 06.04 |
Keywords: | peroxide content; peroxide in styrene; styrene; |
1.1 This test method covers the determination of the peroxide content of styrene monomer reported as hydrogen peroxide.
1.2 This test method has been found applicable to the determination of peroxides in styrene monomer in the range of 1 mg/kg to 60 mg/kg. Based on the precision data in 12.1, LOD is 6 mg/kg and LOQ is 21 mg/kg.
1.3 In determining the conformance of the test results using this method to applicable specifications, results shall be rounded off in accordance with the rounding-off method of Practice E29.
1.4 Units—The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. For specific hazard statements, see Section 7.
1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.