ASTM D7240-18 - Standard Practice for Electrical Leak Location Using Geomembranes with an Insulating Layer in Intimate Contact with a Conductive Layer via Electrical Capacitance Technique (Conductive-Backed Geomembrane Spark Test)

Standard Practice for Electrical Leak Location Using Geomembranes with an Insulating Layer in Intimate Contact with a Conductive Layer via Electrical Capacitance Technique (Conductive-Backed Geomembrane Spark Test)

Format
Availability
Price and currency
English PDF Redline
Immediate download
63.56 EUR
English PDF
Immediate download
52.97 EUR
English Hardcopy
In stock
52.97 EUR
Standard number:D7240-18
Released:01.02.2018
Status:Active
Pages:4
Section:04.13
Keywords:arc testing method; bare geomembrane survey; conductive-backed geomembrane; damage; electrical leak detection method; electrical leak location; electrical leak location method; exposed geomembrane survey; geoelectric leak location; geomembrane; leak detection; leak location survey; leak survey; liner integrity survey; spark testing method; water lance method; water puddle method; ;
DESCRIPTION

1.1 This practice is a performance-based standard for an electrical method for locating leaks in exposed conductive-backed geomembranes. For clarity, this practice uses the term “leak” to mean holes, punctures, tears, knife cuts, seam defects, cracks, and similar breaches in an installed geomembrane (as defined in 3.2.7).

1.2 This practice can be used for conductive-backed geomembranes installed in basins, ponds, tanks, ore and waste pads, landfill cells, landfill caps, canals, and other containment facilities. It is applicable for conductive-backed geomembranes made of materials such as polyethylene, polypropylene, polyvinyl chloride, chlorosulfonated polyethylene, bituminous geomembrane, and any other electrically insulating materials. This practice is best applicable for locating conductive-backed geomembrane leaks where the proper preparations have been made during the construction of the facility.

1.3 For electrical leak location of conductive-backed geomembranes using methods in lieu of or in addition to the spark testing method, the installation must be electrically isolated (as defined in 3.2.5).

1.4 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.5 The spark test may produce an electrical spark and therefore should only be used where an electrical spark would not create a hazard. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.