ASTM D7337_D7337M-12R19 - Standard Test Method for Tensile Creep Rupture of Fiber Reinforced Polymer Matrix Composite Bars
Standard Test Method for Tensile Creep Rupture of Fiber Reinforced Polymer Matrix Composite Bars
Standard number: | ASTM D7337_D7337M-12R19 |
Released: | 01.02.2019 |
Status: | Active |
Pages: | 6 |
Section: | 15.03 |
Keywords: | bars; composite bars; composite materials; creep rupture; rebar; reinforcing bars; tensile properties; tensile strength; |
1.1 This test method outlines requirements for tensile creep rupture testing of fiber reinforced polymer matrix (FRP) composite bars commonly used as tensile elements in reinforced, prestressed, or post-tensioned concrete.
1.2 Data obtained from this test method are used in design of FRP reinforcements under sustained loading. The procedure for calculating the one-million hour creep-rupture capacity is provided in Annex A1.
1.3 The values stated in either SI units or inch-pound units are to be regarded separately as standard. Within the text, the inch-pound units are shown in brackets. The values stated in each system are not exact equivalents; therefore, each system must be used independently of the other. Combining values from the two systems may result in nonconformance with the standard.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.