ASTM E1539-23E01 - Standard Guidance for Use of Radiation-Sensitive Indicators
Standard Guidance for Use of Radiation-Sensitive Indicators
Standard number: | ASTM E1539-23E01 |
Released: | 01.12.2020 |
Status: | Active |
Pages: | 3 |
Section: | 12.02 |
Keywords: | electron beam; gamma radiation; ionizing radiation; irradiation; radiation indicator; radiation processing; radiation-sensitive indicator; X-radiation; X-rays; |
1.1 This document covers procedures for using radiation-sensitive indicators (referred to hereafter as indicators) in radiation processing. These indicators may be labels, papers, inks or packaging materials which undergo a visual change when exposed to ionizing radiation (1-5).2
1.2 The purpose for using indicators is to determine visually whether or not a product has been irradiated, rather than to measure different dose levels.
1.3 Indicators are not dosimeters and should not be used as a substitute for proper dosimetry. Information about dosimetry systems for radiation processing is provided in other ASTM documents (see ASTM Guide 51261).
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.
1.5 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.