ASTM E1664-19 - Standard Classification for Serviceability of an Office Facility for Layout and Building Factors<rangeref></rangeref >

Standard Classification for Serviceability of an Office Facility for Layout and Building Factors<rangeref></rangeref >

Format
Availability
Price and currency
English PDF Redline
Immediate download
79.93 EUR
English PDF
Immediate download
66.45 EUR
English Hardcopy
In stock
66.45 EUR
Standard number:ASTM E1664-19
Released:01.04.2019
Status:Active
Pages:15
Section:04.11
Keywords:building; building layout factors; building loss factors; facility; facility occupants; function; HVAC; layout factors; office; performance; rating; rating scale; requirements; serviceability;
DESCRIPTION

1.1 This classification covers matched sets of scales for classifying an aspect of the serviceability of an office facility, that is, the capability of an office facility to meet certain possible requirements for layout and building factors.

1.2 Within that aspect of serviceability, each matched set of scales, shown in Figs. 1-12, are for classifying one topic of serviceability. Each topic is typically broken down into two or more demand functions or supply features. Each paragraph in an Occupant Requirement Scale (see Figs. 1-12) summarizes one level of serviceability on that function, which occupants might require. The matching entry in the Facility Rating Scale (see Figs. 1-12) is a translation of the requirement into a description of certain features of a facility which, taken in combination, indicate that the facility is likely to meet that level of required serviceability.

FIG. 1 Demand Scale A.7.1.1 for Constraints on Layout

Demand Scale A.7.1.1 for Constraints on LayoutDemand Scale A.7.1.1 for Constraints on Layout

FIG. 2 Demand Scale A.7.1.2 for Constraints of Population Density

Demand Scale A.7.1.2 for Constraints of Population
 DensityDemand Scale A.7.1.2 for Constraints of Population
 Density

FIG. 3 Demand Scale A.7.1.3 for Cost of Upgrade

Demand Scale A.7.1.3 for Cost of UpgradeDemand Scale A.7.1.3 for Cost of Upgrade

FIG. 4 Supply Scale A.7.1.1 for Constraints on Layout

Supply Scale A.7.1.1 for Constraints on LayoutSupply Scale A.7.1.1 for Constraints on Layout

FIG. 5 Supply Scale A.7.1.2 for Population Density Supported

Supply Scale A.7.1.2 for Population Density SupportedSupply Scale A.7.1.2 for Population Density Supported

FIG. 6 Supply Scale A.7.1.3 for Cost of Upgrade

Supply Scale A.7.1.3 for Cost of UpgradeSupply Scale A.7.1.3 for Cost of Upgrade

FIG. 7 Demand Scale A.7.2.1 for Tolerance of Sound and Visual Conditions

Demand Scale A.7.2.1 for Tolerance of Sound and Visual
 ConditionsDemand Scale A.7.2.1 for Tolerance of Sound and Visual
 Conditions

FIG. 8 Demand Scale A.7.2.2 Avoiding Glare on Monitors

Demand Scale A.7.2.2 Avoiding Glare on MonitorsDemand Scale A.7.2.2 Avoiding Glare on Monitors

FIG. 9 Supply Scale A.7.2.1 Constraints on Layout

Supply Scale A.7.2.1 Constraints on LayoutSupply Scale A.7.2.1 Constraints on Layout

FIG. 10 Supply Scale A.7.2.2 Avoiding Glare on Monitors

Supply Scale A.7.2.2 Avoiding Glare on MonitorsSupply Scale A.7.2.2 Avoiding Glare on Monitors

FIG. 11 Demand Scale A.7.3 for Influence of Building Loss Features on Space Needs

Demand Scale A.7.3 for Influence of Building Loss Features
 on Space NeedsDemand Scale A.7.3 for Influence of Building Loss Features
 on Space Needs

FIG. 12 Supply Scale A.7.3 Influence of Building Loss Features on Space Needs

Supply Scale A.7.3 Influence of Building Loss Features
 on Space NeedsSupply Scale A.7.3 Influence of Building Loss Features
 on Space Needs

1.3 The entries in the Facility Rating Scale (see Figs. 1-12) are indicative and not comprehensive. They are for quick scanning to estimate approximately, quickly, and economically, how well an office facility is likely to meet the needs of one or another type of occupant group over time. The entries are not for measuring, knowing, or evaluating how an office facility is performing.

1.4 This classification can be used to estimate the level of serviceability of an existing facility. It can also be used to estimate the serviceability of a facility that has been planned but not yet built, such as one for which single-line drawings and outline specifications have been prepared.

1.5 This classification indicates what would cause a facility to be rated at a certain level of serviceability but does not state how to conduct a serviceability rating nor how to assign a serviceability score. That information is found in Practice E1679. The scales in this classification are complimentary to and compatible with Practice E1679. Each requires the other.

1.6 The scales are intended to identify the levels of various requirements unique to a particular user, and the serviceability (capability) of a building to meet those requirements. The scales thus supplement rather than include code requirements. It remain the responsibility of designers, builders, and building managers to meet applicable code requirements relative to their respective roles in facility design, construction, and ongoing management.

1.7 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.

1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.