PRICES include / exclude VAT
Homepage>ASTM Standards>67>67.250>ASTM F1308-98R23 - Standard Test Method for Quantitating Volatile Extractables in Microwave Susceptors Used for Food Products
Sponsored link
Released: 01.04.2023

ASTM F1308-98R23 - Standard Test Method for Quantitating Volatile Extractables in Microwave Susceptors Used for Food Products

Standard Test Method for Quantitating Volatile Extractables in Microwave Susceptors Used for Food Products

Format
Availability
Price and currency
English PDF
Immediate download
60.67 EUR
English Hardcopy
In stock
60.67 EUR
Standard number:ASTM F1308-98R23
Released:01.04.2023
Status:Active
Pages:5
Section:15.10
Keywords:extractables, volatile, quantitation, in microwave susceptors; fluoroptic thermometry; gas chromatography, static headspace; microwave susceptors; microwave suseptors, volatile extractables in; susceptors, microwave; volatile extractables, quantitation, in microwave susceptors;
DESCRIPTION

1.1 This test method covers complete microwave susceptors.

1.2 This test method covers a procedure for quantitating volatile compounds whose identity has been established and which are evolved when a microwave susceptor sample is tested under simulated use conditions.

1.3 This test method was collaboratively evaluated with a variety of volatile compounds (see statistical evaluation). For compounds other than those evaluated, the analyst should determine the sensitivity and reproducibility of the method by carrying out appropriate spike and recovery studies. The analyst is referred to Practice E260 for guidance.

1.4 For purposes of verifying the identity of or identifying unknown volatile compounds, the analyst is encouraged to incorporate techniques such as gas chromatography/mass spectroscopy, gas chromatography/infrared spectroscopy, or other techniques in conjunction with this test method.

1.5 A sensitivity level of approximately 0.025 μg/in.2 is achievable for the compounds studied in Table 1. Where other compounds are being quantitated and uncertainty exists over method sensitivity, the analyst is referred to Practice E260 for procedures on determining sensitivity of chromatographic methods.

1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Specific safety hazards warnings are given in 10.2, 11.1, and 11.6.

1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.