PRICES include / exclude VAT
Homepage>ASTM Standards>11>11.140>ASTM F2407_F2407M-23A - Standard Specification for Surgical Gowns Intended for Use in Healthcare Facilities
Sponsored link
Released: 01.06.2023

ASTM F2407_F2407M-23A - Standard Specification for Surgical Gowns Intended for Use in Healthcare Facilities

Standard Specification for Surgical Gowns Intended for Use in Healthcare Facilities

Format
Availability
Price and currency
English PDF Redline
Immediate download
79.93 EUR
English PDF
Immediate download
66.45 EUR
English Hardcopy
In stock
66.45 EUR
Standard number:ASTM F2407_F2407M-23A
Released:01.06.2023
Status:Active
Pages:11
Section:11.03
Keywords:barrier performance; critical zone; healthcare; hydrostatic pressure; impact penetration; physical properties; protective clothing; surgical gown; viral penetration resistance;
DESCRIPTION

1.1 This specification establishes requirements for the performance, documentation, and labeling of surgical gowns used in healthcare facilities. Four levels of barrier properties for surgical gowns are specified in ANSI/AAMI PB70 and are included in this specification for reference purposes.

Note 1: Some properties require minimum performance and others are for documentation only.

Note 2: ANSI/AAMI PB70 evaluates the barrier properties of surgical gown fabrics using water only in Levels 1, 2, and 3. Since surgical gowns are exposed to blood and other fluids with different surface tensions, the performance of additional testing to identify the barrier levels to simulated biological fluids is required for a Level 4 gown.

1.2 This specification does not cover all the requirements that a healthcare facility deems necessary to select a product, nor does it address criteria for evaluating experimental products.

1.3 This specification is not intended to serve as a detailed manufacturing or purchase specification, but can be referenced in purchase specifications as the basis for selecting test requirements.

1.4 The values stated in SI units or in other units shall be regarded separately as standard. The values stated in each system must be used independently of the other, without combining values in any way.

1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.6 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.