ASTM F2477-24 - Standard Test Methods for <emph type="ital"> in vitro</emph> Pulsatile Durability Testing of Vascular Stents and Endovascular Prostheses

Standard Test Methods for <emph type="ital"> in vitro</emph> Pulsatile Durability Testing of Vascular Stents and Endovascular Prostheses

Format
Availability
Price and currency
English PDF Redline
Immediate download
79.93 EUR
English PDF
Immediate download
66.45 EUR
English Hardcopy
In stock
66.45 EUR
Standard number:ASTM F2477-24
Released:15.07.2024
Status:Active
Pages:14
Section:13.01
Keywords:durability test; endovascular cardiology; endovascular prostheses; fatigue test; interventional cardiology; intravascular device test; pressure control; pulsatile fatigue; stent durability; stent fatigue; stent test; strain control; vascular stent;
DESCRIPTION

1.1 These test methods cover the determination of the durability of a vascular stent or endoprosthesis by exposing it to diametric deformation by means of hydrodynamic pulsatile loading. This testing occurs on a test sample that has been deployed into a mock (elastically simulated) vessel. The test is conducted for a number of cycles to adequately establish the intended fatigue resistance of the sample.

1.2 These test methods are applicable to balloon-expandable and self-expanding stents fabricated from metals and metal alloys and endovascular prostheses with metal stents. This standard does not specifically address any attributes unique to coated stents, polymeric stents, or biodegradable stents, although the application of this test method to those products is not precluded.

1.3 These test methods may be used for assessing stent and endovascular prosthesis durability when exposed to blood vessel cyclic diametric change. These test methods do not address other cyclic loading modes such as bending, torsion, extension, or compression.

1.4 These test methods are primarily intended for use with physiologically relevant diametric change, however guidance is provided for hyper-physiologic diametric deformation (that is, fatigue to fracture).

1.5 These test methods do address test conditions for curved mock vessels, however might not address all concerns.

1.6 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.

1.7 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use.

1.8 This international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for the Development of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.