PRICES include / exclude VAT
Homepage>BS Standards>27 ENERGY AND HEAT TRANSFER ENGINEERING>27.060 Burners. Boilers>27.060.30 Boilers and heat exchangers>BS 1894:1992 Specification for design and manufacture of electric boilers of welded construction
Sponsored link
immediate downloadReleased: 1992-12-15
BS 1894:1992 Specification for design and manufacture of electric boilers of welded construction

BS 1894:1992

Specification for design and manufacture of electric boilers of welded construction

Format
Availability
Price and currency
English Secure PDF
Immediate download
399.30 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
39.93 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
119.79 EUR
English Hardcopy
In stock
399.30 EUR
Standard number:BS 1894:1992
Pages:100
Released:1992-12-15
ISBN:0 580 21033 2
Status:Standard
DESCRIPTION

BS 1894:1992


This standard BS 1894:1992 Specification for design and manufacture of electric boilers of welded construction is classified in these ICS categories:
  • 27.060.30 Boilers and heat exchangers

1.1.1 This British Standard specifies requirements for the design and manufacture, including materials, workmanship, inspection, testing, documentation and marking, of boilers utilizing electrical energy by the use of electrodes or immersion elements. The boilers dealt with are of cylindrical design, either horizontal or vertical, constructed from carbon or carbon manganese steels by fusion welding for which the limits of application are given in table 1.1.1.

Table 1.1.1. Limits of application
Classification Limit
Class I Steam and hot water boilers which exceed the limitations specified for class II and class III boilers
Class II Steam and hot water boilers the design pressure of which does not exceed 1.14 N/mm2 and the design pressure of which (in N/mm2), multiplied by the internal diameter in millimetres, does not exceed 1450
Class III

Steam boilers the design pressure of which does not exceed 0.23 N/mm2

Unvented hot water boilers the design pressure of which does not exceed 0.45 N/mm2

Vented hot water boilers the design pressure of which does not exceed 0.77 N/mm2

The standard applies to electric boilers which provide hot water, steam or superheated steam for use in industrial and commercial applications.

NOTE. Notwithstanding the materials quoted above this does not preclude the use of other materials, such as stainless steels or copper, copper linings, etc. (see 2.1) where the boiler otherwise falls within the limits of this specification, taking the allowable stresses from another appropriate specification.

1.1.2 In addition to the definitive requirements, this standard also requires the items detailed in 1.6 to be documented. For compliance with this standard, both the definitive requirements and the documented items have to be satisfied.


Includes materials, workmanship, inspection, testing, documentation and marking of boilers utilizing electrodes or immersion elements to provide hot water, steam or superheated steam. The boilers are of cylindrical design, constructed from carbon or carbon manganese steels by fusion welding.