PRICES include / exclude VAT
Homepage>BS Standards>91 CONSTRUCTION MATERIALS AND BUILDING>91.060 Elements of buildings>91.060.30 Ceilings. Floors. Stairs>BS 585-1:1989 Wood stairs Specification for stairs with closed risers for domestic use, including straight and winder flights and quarter or half landings
Sponsored link
immediate downloadReleased: 1989-06-30
BS 585-1:1989 Wood stairs Specification for stairs with closed risers for domestic use, including straight and winder flights and quarter or half landings

BS 585-1:1989

Wood stairs Specification for stairs with closed risers for domestic use, including straight and winder flights and quarter or half landings

Format
Availability
Price and currency
English Secure PDF
Immediate download
266.20 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
26.62 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
79.86 EUR
English Hardcopy
In stock
266.20 EUR
Standard number:BS 585-1:1989
Pages:28
Released:1989-06-30
ISBN:0 580 16566 3
Status:Standard
DESCRIPTION

BS 585-1:1989


This standard BS 585-1:1989 Wood stairs is classified in these ICS categories:
  • 91.060.30 Ceilings. Floors. Stairs

This Part of BS 585 specifies materials and construction requirements for stairs constructed of timber, which may include plywood risers and treads and/or edge-to-edge jointed timber and/or glue-laminated wood components. It applies to stairs intended primarily for use inside one-family dwellings, including one or more of the following:

  1. straight flights;

  2. winder flights;

  3. quarter landings;

  4. half landings.

This Part of BS 585 does not apply to stairs with open risers, stairs having an overall width greater than 1 220 mm, or stairs having a total going in one flight exceeding 3 800 mm.

Appendix A gives recommendations for site fixing of stairs.

Appendix B gives recommendations for the design of stairs with winder flights.

NOTE 1 For stairs constructed of wood-based materials, see BS 585-2.

NOTE 2 For guidance on the design of straight stairs, see BS 5395-1.

NOTE 3 The titles of the publications referred to in this standard are listed on the inside back cover.


Includes plywood risers and treads, edge-to-edge jointed timber and glue-laminated wood components. Recommendations for fixing stairs on site and for the design of stairs with winder flights. Open risers, stairs wider than 122 mm and flights having a total going exceeding 3800 mm are excluded.