BS 6783-1:1986
Sampling and analysis of nickel, ferronickel and nickel alloys Method for determination of silver, bismuth, cadmium, cobalt, copper, iron, manganese, lead and zinc in nickel by flame atomic absorption spectrometry
Standard number: | BS 6783-1:1986 |
Pages: | 16 |
Released: | 1986-12-31 |
ISBN: | 0 580 15520 X |
Status: | Standard |
BS 6783-1:1986
This standard BS 6783-1:1986 Sampling and analysis of nickel, ferronickel and nickel alloys is classified in these ICS categories:
- 77.120.40 Nickel, chromium and their alloys
This International Standard specifies a flame atomic absorption spectrometric method for the determination of the silver, bismuth, cadmium, cobalt, copper, iron, manganese, lead and zinc contents of refined, wrought and cast nickel within the ranges specified in Table 1. This method is applicable to the independent determination of any one or more of the elements listed without including all the elements specified in the standard solutions.
Table 1 – Concentration ranges of elements to be determined
Element | Concentration range, [% (m/m)]a | |
Procedure A | Procedure B | |
Ag | 0,000 2 to 0,01 | – |
Bi | 0,000 1 to 0,01 | – |
Cd | 0,000 2 to 0,002 5 | – |
Co | 0,001 0 to 0,01 | to 1,00 |
Cu | 0,000 2 to 0,01 | 0,01 to 1,00 |
Fe | 0,002 5 to 0,01 | 0,01 to 0,15 |
Mn | 0,000 5 to 0,01 | 0,01 to 0,20 |
Pb | 0,000 5 to 0,01 | – |
Zn | 0,000 2 to 0,002 5 | 0,00 1 to 0,01 5 |
a For specific compositions, see ISO 6283. |
The lower level for iron can be extended to less than 0,002 5 % (m/m) provided nickel containing less than 0,000 1 % (m/m) iron is used for preparation of standard solutions; see 4.1.
The upper limit for the determination of cobalt and copper can be raised to 2 % (m/m) by a minor modification to the method; see 11.1.
For potential interferences, see clause 10.
For refined, wrought and cast nickel; ranges for elements to be determined are specified.