PRICES include / exclude VAT
Homepage>BS Standards>29 ELECTRICAL ENGINEERING>29.120 Electrical accessories>29.120.20 Connecting devices>BS 7197:1990 Specification for performance of bonds for electric power cable terminations and joints for system voltages up to 36 kV
Sponsored link
immediate downloadReleased: 1990-06-29
BS 7197:1990 Specification for performance of bonds for electric power cable terminations and joints for system voltages up to 36 kV

BS 7197:1990

Specification for performance of bonds for electric power cable terminations and joints for system voltages up to 36 kV

Format
Availability
Price and currency
English Secure PDF
Immediate download
191.18 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
19.12 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
57.35 EUR
English Hardcopy
In stock
191.18 EUR
Standard number:BS 7197:1990
Pages:18
Released:1990-06-29
ISBN:0 580 17788 2
Status:Standard
DESCRIPTION

BS 7197:1990


This standard BS 7197:1990 Specification for performance of bonds for electric power cable terminations and joints for system voltages up to 36 kV is classified in these ICS categories:
  • 29.120.20 Connecting devices

This British Standard specifies requirements for bonds for connecting the metallic envelopes (protective conductors) of electric power cables at terminations and joints for system voltages up to 36 kV for the different types of cables covered by British Standards.

The standard describes performance test methods, tables cross-sectional areas of solid copper, aluminium and steel bonds calculated in accordance with a given formula and gives guidance on matters which affect the following.

  1. Provision of a circuit in joints between cables and between a cable and its terminal equipment for the transmission of currents which may arise under system fault conditions.
  2. Provision of bonding for neutral conductors (CNE only).
  3. Provision of overall protective conductors at joints to provide for the passage of a fault current in the event of mechanical damage or failure of the insulation and to contain the electric field around high voltage conductors.

Guidance on bonding is given in Appendix A.

The standard specifically excludes additional safety precautions necessary when jointing live cables.

NOTE The title of the publication referred to in this standard is given on the inside back cover.


Specifies bonds for connecting the metallic envelopes of electric power cables at terminations and joints. Gives performance test methods and tables cross-sectional area of solid copper, aluminium and steel bonds together with guidance on bonding.