Don't have a credit card? Never mind we support BANK TRANSFER .

PRICES include / exclude VAT
immediate downloadReleased: 2022-07-25
BS EN 12350-7:2019 Testing fresh concrete Air content. Pressure methods

BS EN 12350-7:2019

Testing fresh concrete Air content. Pressure methods

Format
Availability
Price and currency
English Secure PDF
Immediate download
253.00 EUR
English Hardcopy
In stock
253.00 EUR
Standard number:BS EN 12350-7:2019
Pages:28
Released:2022-07-25
ISBN:978 0 539 23092 5
Status:Standard
BS EN 12350-7:2019 Testing fresh concrete Air content. Pressure methods

BS EN 12350-7:2019 Testing Fresh Concrete Air Content. Pressure Methods

Standard Number: BS EN 12350-7:2019

Pages: 28

Released: 2022-07-25

ISBN: 978 0 539 23092 5

Name: Testing Fresh Concrete Air Content. Pressure Methods

Status: Standard

Overview

Ensure the quality and durability of your concrete with the BS EN 12350-7:2019 standard, a comprehensive guide to testing the air content in fresh concrete using pressure methods. This standard is essential for professionals in the construction and civil engineering industries who are committed to maintaining the highest standards of concrete quality.

Why Choose BS EN 12350-7:2019?

The air content of fresh concrete is a critical factor that influences its strength, durability, and overall performance. The BS EN 12350-7:2019 standard provides a detailed methodology for accurately measuring the air content, ensuring that your concrete meets the necessary specifications and performs optimally in various conditions.

Key Features

  • Comprehensive Coverage: With 28 pages of detailed instructions and guidelines, this standard covers all aspects of testing air content in fresh concrete using pressure methods.
  • Up-to-Date Information: Released on 2022-07-25, this standard reflects the latest advancements and best practices in the field.
  • International Recognition: As a part of the BS EN series, this standard is recognized and respected globally, ensuring that your practices align with international benchmarks.
  • ISBN: 978 0 539 23092 5, making it easy to reference and locate in professional and academic settings.

Benefits of Using BS EN 12350-7:2019

Implementing the BS EN 12350-7:2019 standard in your concrete testing procedures offers numerous benefits:

  • Enhanced Quality Control: By following the precise methods outlined in this standard, you can ensure consistent and reliable measurement of air content, leading to higher quality concrete.
  • Improved Durability: Proper air content measurement helps in producing concrete that is more resistant to environmental factors, thereby extending its lifespan.
  • Compliance: Adhering to this standard ensures that your concrete testing methods comply with industry regulations and standards, avoiding potential legal and financial repercussions.
  • Professional Credibility: Utilizing a recognized standard like BS EN 12350-7:2019 enhances your professional reputation and demonstrates your commitment to excellence.

Who Should Use This Standard?

This standard is indispensable for a wide range of professionals, including:

  • Civil Engineers: Ensure the structural integrity and longevity of your projects by accurately measuring the air content in fresh concrete.
  • Construction Managers: Maintain high standards of quality control on-site by implementing the best practices outlined in this standard.
  • Quality Assurance Teams: Use this standard as a benchmark for testing procedures to guarantee the consistency and reliability of your concrete products.
  • Academic Researchers: Reference this standard in your studies and research to align with the latest industry practices and advancements.

Detailed Methodology

The BS EN 12350-7:2019 standard provides a step-by-step guide to the pressure method for testing air content in fresh concrete. This method involves the use of a pressure meter to determine the volume of air voids within the concrete mix. The standard outlines the necessary equipment, preparation procedures, and testing steps to ensure accurate and reliable results.

Equipment and Preparation

To perform the air content test using the pressure method, the following equipment is required:

  • Pressure meter
  • Concrete sample container
  • Calibration vessel
  • Water and air supply

The standard provides detailed instructions on how to prepare the equipment and concrete sample to ensure that the test is conducted under optimal conditions.

Testing Procedure

The testing procedure involves several key steps:

  1. Fill the concrete sample container with fresh concrete.
  2. Attach the pressure meter to the container and ensure a secure seal.
  3. Apply pressure to the sample and record the air content reading from the meter.
  4. Repeat the test as necessary to verify the accuracy of the results.

Each step is described in detail in the standard, ensuring that users can perform the test with confidence and precision.

Conclusion

The BS EN 12350-7:2019 standard is an essential resource for anyone involved in the testing and quality control of fresh concrete. By providing a detailed methodology for measuring air content using pressure methods, this standard helps ensure that your concrete meets the highest standards of quality and performance. Whether you are a civil engineer, construction manager, quality assurance professional, or academic researcher, this standard is a valuable addition to your professional toolkit.

DESCRIPTION

BS EN 12350-7:2019


This standard BS EN 12350-7:2019 Testing fresh concrete is classified in these ICS categories:
  • 91.100.30 Concrete and concrete products
This document describes two methods for determination of air content of compacted fresh concrete, made with normal weight or relatively dense aggregate and having a declared value of D of the coarsest fraction of aggregates actually used in the concrete (Dmax) not greater than 63 mm. The test is not suitable for concretes with slumps less than 10 mm according to EN 12350-2. Neither method is applicable to concretes made with lightweight aggregates, air cooled blast-furnace slag, or aggregates with high porosity, because of the magnitude of the aggregate correction factor, compared with the entrained air content of the concrete.