Homepage>BS Standards>91 CONSTRUCTION MATERIALS AND BUILDING>91.140 Installations in buildings>91.140.30 Ventilation and air-conditioning systems>BS EN 13141-8:2022 - TC Tracked Changes. Ventilation for buildings. Performance testing of components/products for residential ventilation Performance testing of non-ducted mechanical supply and exhaust ventilation units (including heat recovery)
Sponsored link
immediate downloadReleased: 2022-10-18
BS EN 13141-8:2022 - TC Tracked Changes. Ventilation for buildings. Performance testing of components/products for residential ventilation Performance testing of non-ducted mechanical supply and exhaust ventilation units (including heat recovery)

BS EN 13141-8:2022 - TC

Tracked Changes. Ventilation for buildings. Performance testing of components/products for residential ventilation Performance testing of non-ducted mechanical supply and exhaust ventilation units (including heat recovery)

Format
Availability
Price and currency
English Secure PDF
Immediate download
520.30 EUR
English Hardcopy
In stock
520.30 EUR
Standard number:BS EN 13141-8:2022 - TC
Pages:150
Released:2022-10-18
ISBN:978 0 539 24135 8
Status:Tracked Changes
DESCRIPTION

BS EN 13141-8:2022 - TC


This standard BS EN 13141-8:2022 - TC Tracked Changes. Ventilation for buildings. Performance testing of components/products for residential ventilation is classified in these ICS categories:
  • 91.140.30 Ventilation and air-conditioning systems
This document specifies the laboratory test methods and test requirements for the testing of aerodynamic, thermal, acoustic and the electrical performance characteristics of non-ducted mechanical supply and exhaust residential ventilation units used in single dwellings. The purpose of this document is not to consider the quality of ventilation but to test the performance of the equipment. This document is applicable to ventilation units, the latter: a) containing either: - fans for mechanical supply and exhaust; - air filters; - air-to-air heat exchanger for heat and possibly humidity recovery; - control system; - inlet and outlet grilles; or - alternating heat exchangers which provide separate supply and exhaust air flows; b) provided either: - in one assembly; or - in more than one assembly, the separate assemblies of which are designed to be used together. This document does not deal with ducted units which are covered by EN 13141-7 or units with heat pumps. Safety requirements are given in EN 60335-2-40 and EN 60335-2-80.