PRICES include / exclude VAT
Homepage>BS Standards>13 ENVIRONMENT. HEALTH PROTECTION. SAFETY>13.040 Air quality>13.040.40 Stationary source emissions>BS EN 14790:2017 Stationary source emissions. Determination of the water vapour in ducts. Standard reference method
Sponsored link
immediate downloadReleased: 2017-01-31
BS EN 14790:2017 Stationary source emissions. Determination of the water vapour in ducts. Standard reference method

BS EN 14790:2017

Stationary source emissions. Determination of the water vapour in ducts. Standard reference method

Format
Availability
Price and currency
English Secure PDF
Immediate download
331.20 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
33.12 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
99.36 EUR
English Hardcopy
In stock
331.20 EUR
Standard number:BS EN 14790:2017
Pages:48
Released:2017-01-31
ISBN:978 0 580 85052 3
Status:Standard
DESCRIPTION

BS EN 14790:2017


This standard BS EN 14790:2017 Stationary source emissions. Determination of the water vapour in ducts. Standard reference method is classified in these ICS categories:
  • 13.040.40 Stationary source emissions

This European Standard specifies the standard reference method (SRM) based on a sampling system with a condensation/adsorption technique to determine the water vapour concentration in the flue gases emitted to atmosphere from ducts and stacks.

This European Standard specifies the performance characteristics to be determined and performance criteria to be fulfilled by measuring systems based on the measurement method. It applies to periodic monitoring and to the calibration or control of automated measuring systems (AMS) permanently installed on a stack, for regulatory or other purposes.

This European Standard specifies criteria for demonstration of equivalence of an alternative method to the SRM by application of EN 14793:2017 .

This European Standard is applicable in the range of water vapour content from 4 % to 40 % as volume concentrations and of water vapour mass concentration from 29 g/m 3 to 250 g/m 3 as a wet gas, although for a given temperature the upper limit of the method is related to the maximum pressure of water in air or in the gas.

In this European Standard all the concentrations are expressed at standard conditions (273 K and 101,3 kPa).

NOTE 1

For saturated conditions the condensation/adsorption method is not applicable. Some guidance is given in this European Standard to deal with flue gas when droplets are present.

This European Standard has been validated during field tests on waste incineration, co-incineration and large combustion plants. It has been validated for sampling periods of 30 min in the volume concentration range of 7 % to 26 %.

NOTE 2

The characteristics of installations, the conditions during field tests and the values of repeatability and reproducibility in the field are given in Annex A.