BS EN 15096:2020
Devices to prevent pollution by backflow of potable water. Hose Union anti-vacuum valves. DN 15 to DN 25 inclusive Family H, type B and type D. General technical specification
Standard number: | BS EN 15096:2020 |
Pages: | 26 |
Released: | 2020-07-06 |
ISBN: | 978 0 539 02747 1 |
Status: | Standard |
BS EN 15096:2020
This standard BS EN 15096:2020 Devices to prevent pollution by backflow of potable water. Hose Union anti-vacuum valves. DN 15 to DN 25 inclusive Family H, type B and type D. General technical specification is classified in these ICS categories:
- 13.060.20 Drinking water
- 91.140.60 Water supply systems
- 23.060.01 Valves in general
This document specifies:
-
the field of application;
-
the requirements of hose union anti vacuum valves;
-
dimensional and physio-chemical properties, and properties of general hydraulic, mechanical and acoustic design of hose union anti-vacuum valves of nominal sizes DN 15 up to and including DN 25;
-
marking and technical product information.
This document specifies the characteristics of hose union anti-vacuum valves of nominal size DN 15 up to and including DN 25 that are suitable for use in drinking water systems at pressures up to and including 1 MPa (10 bar) and temperatures up to and including 65 °C and for 1 h at 90 °C.
HB protects against back siphonage only and is installed in vertical downward flow position.
HD protects against back flow and is installed in vertical downward flow position.
HB and HD anti-vacuum valves are for installation exclusively at the connecting point between stop valve and hose in vertical downward flow position.