BS EN 15544:2023 One off Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves). Dimensioning
Introducing the BS EN 15544:2023 One off Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves). Dimensioning, a comprehensive guide that provides detailed instructions on the dimensioning of tiled and mortared stoves. This standard is a must-have for professionals in the heating and construction industry, as well as DIY enthusiasts who want to ensure their projects meet the highest standards of safety and efficiency.
Released on 2023-02-28, this standard is the latest in the series, reflecting the most recent advancements in stove technology and construction techniques. With 28 pages of in-depth information, it provides a thorough understanding of the dimensioning process, ensuring that your stove is built to the optimal size for maximum heat output and minimal energy consumption.
Key Features
The BS EN 15544:2023 standard offers a wealth of information, including:
- Comprehensive guidelines on the dimensioning of tiled and mortared stoves, ensuring optimal performance and safety.
- Clear, easy-to-follow instructions that are suitable for both professionals and DIY enthusiasts.
- Up-to-date information that reflects the latest advancements in stove technology and construction techniques.
- A thorough understanding of the factors that influence stove size, including heat output, energy consumption, and safety considerations.
Why Choose BS EN 15544:2023?
Choosing the BS EN 15544:2023 standard ensures that your stove is built to the highest standards of safety and efficiency. Whether you're a professional in the heating and construction industry or a DIY enthusiast, this standard provides the information you need to ensure your stove is dimensioned correctly.
With its clear, easy-to-follow instructions, the BS EN 15544:2023 standard takes the guesswork out of stove dimensioning. It provides a thorough understanding of the factors that influence stove size, ensuring that your stove is built to the optimal size for maximum heat output and minimal energy consumption.
Furthermore, by choosing the BS EN 15544:2023 standard, you're choosing a resource that reflects the latest advancements in stove technology and construction techniques. This ensures that your stove is built using the most up-to-date methods, resulting in a more efficient, safer, and longer-lasting stove.
Order Your Copy Today
Don't miss out on this essential resource. Order your copy of the BS EN 15544:2023 One off Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves). Dimensioning today and ensure your stove is built to the highest standards of safety and efficiency.
The standard is available in a convenient digital format with an ISBN of 978 0 539 16440 4. It's time to take your stove construction to the next level. Order your copy today!
BS EN 15544:2023
This standard BS EN 15544:2023 One off Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves). Dimensioning is classified in these ICS categories:
- 97.100.30 Solid fuel heaters
The application of the calculations of this document enables a verification of the emission values carbon monoxide, nitrogen dioxide, organically bound carbon as well as dust and the energy efficiency. Complying with the calculations of this document results in emission values less or equal for carbon monoxide 1 500 mg/mn3 (1 000 mg/MJ), nitrogen dioxide 225 mg/mn3 (150 mg/MJ), organically bound carbon 120 mg/mn3 (80 mg/MJ) and dust 90 mg/mn3 (60 mg/MJ). If the calculations of this document are used in combination with suitable combustion chambers that prove lower emission values in a type test, these values are also considered to be complied with. The user shall be aware that there might be national or local regulations, which impose stricter legal emissions and/or efficiency requirements. This document specifies calculations for the dimensioning of Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) based upon the required nominal heat output of the stove as declared by the producer. The Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) are of individual one-off construction design. The document can be used for log wood fired Kachelgrundöfen/Putzgrundöfen (tiled/plastered stoves) that burn one fuel load per storage period with a maximum load between 10 kg and 40 kg (log wood with water content from 12 % to 20 %, thickness of 5 cm to 10 cm in diameter, length varies usually from 25 cm to 50 cm, and is oriented toward the combustion chamber dimensions) and a storage period (nominal heating time) between 8 h and 24 h. This document is applicable for Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) equipped with fireclay as interior material, with an apparent density between 1,750 kg/m3 and 2,300 kg/m3, a degree of porosity from 17 % up to 33 % by volume and a heat conductivity from 0,90 W/mK up to 1,35 W/mK (temperature range 20 °C to 400 °C). This document is applicable for Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) with combustion air supply from the side via a firebox door frame or the standing grate of the heating door into the combustion chamber. The document is applicable for an inflow speed of the combustion air between 2 m/s and 4 m/s. This document also applies to the combination with combustion chambers that are suitable for one-off Kachelgrundöfen/Putzgrundöfen (tiled/mortared stoves) and for which compliance with the legally required emission values has been verified as part of a type test by an accredited and/or notified body. The following general conditions apply to such combustion chambers: - with an air-fuel ratio of between 1,95 and 3,95 according to the type test; - with a maximum load from 5 kg to 40 kg; - using other suitable materials as well as fireclay. With regard to the type test, this document is applicable for combustion chambers which are tested: - according to EN 15250 (or prEN 16510-2-5); - according to EN 13229 (or prEN 16510-2-2); or - according to respective national standards (e.g. ÖNORM B 8303). This document is applicable for type tested combustion chambers designed for batch fired pellet burning if meeting the requirements according to this document (air-fuel ratio between 1,95 and 3,95, the load of the pellets shall be burned in (78 ± 20) min). This document is not applicable for: - combinations with water heat exchangers for central heating or other heat absorbing elements like open water tanks etc.; - combustion chambers with glass plates greater than 1/5 of the combustion chamber surface; - mass-produced prefabricated stoves (slow heat release appliances) or partly prefabricated stoves (slow heat release appliances) according to EN 15250 (or prEN 16510-2-5).