PRICES include / exclude VAT
Homepage>BS Standards>91 CONSTRUCTION MATERIALS AND BUILDING>91.140 Installations in buildings>91.140.70 Sanitary installations>BS EN 16146:2012+A1:2014 Sanitary tapware. Extractable shower hoses for sanitary tapware for supply systems type 1 and type 2. General technical specification
Sponsored link
immediate downloadReleased: 2014-12-31
BS EN 16146:2012+A1:2014 Sanitary tapware. Extractable shower hoses for sanitary tapware for supply systems type 1 and type 2. General technical specification

BS EN 16146:2012+A1:2014

Sanitary tapware. Extractable shower hoses for sanitary tapware for supply systems type 1 and type 2. General technical specification

Format
Availability
Price and currency
English Secure PDF
Immediate download
249.60 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
24.96 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
74.88 EUR
English Hardcopy
In stock
249.60 EUR
Standard number:BS EN 16146:2012+A1:2014
Pages:30
Released:2014-12-31
ISBN:978 0 580 85652 5
Status:Standard
DESCRIPTION

BS EN 16146:2012+A1:2014


This standard BS EN 16146:2012+A1:2014 Sanitary tapware. Extractable shower hoses for sanitary tapware for supply systems type 1 and type 2. General technical specification is classified in these ICS categories:
  • 91.140.70 Sanitary installations

This European Standard applies to hoses for extractable outlets of any material intended for equipping sanitary tapware for sinks and basins. Such hoses will only be connected downstream of the obturator of the tapware. The tapware will comply with EN 200 , EN 817 , EN 1111 , EN 1286 or EN 1287 (see [1], [2], [3], [5] and [6]).

Hoses intended to connect sanitary tapware to the water supplies are not covered by this standard.

This European Standard specifies:

  • the dimensional, mechanical and hydraulic characteristics with which the hose for extractable outlets shall comply;

  • the procedures for testing these characteristics.

Details of pressures and temperatures are given in Table 1.

Table 1
Conditions of use/Classifications
Water supply system Operating range of hoses for extractable outlets Flow rates (Q) a
Limits Recommended
Type 1

see Figure 1

Dynamic Pressure

0,05 MPa ≤ P ≤ 0,5 MPa

(0,5 bar ≤ P ≤ 5 bar)
Dynamic Pressure

0,1 MPa to 0,3 MPa

(1,0 bar to 3,0 bar)
Class 1:

Q ≥ 0,25 l/s (15 l/min)

Class 2:

Q ≥ 0,15 l/s (9 l/min)

Type 2

see Figure 2

Dynamic Pressure

0,01 MPa to 0,2 MPa (0,1 bar to 2,0 bar)

Dynamic Pressure

0,02 MPa to 0,10 MPa (0,2 bar to 1,0 bar)

Class E:

0,06 l/s < Q < 0,18 l/s

(3,6 l/min < Q < 10,8 l/min.)
Class H:

0,18 l/s ≤ Q (10,8 l/min ≤ Q)

Temperature T ≤ 70°C T ≤ 60°C
a

See details in Table 3.

[Image removed.]

[Image removed.]