PRICES include / exclude VAT
Homepage>BS Standards>91 CONSTRUCTION MATERIALS AND BUILDING>91.120 Protection of and in buildings>91.120.10 Thermal insulation>BS EN 16798-5-1:2017 Energy performance of buildings. Ventilation for buildings Calculation methods for energy requirements of ventilation and air conditioning systems (Modules M5-6, M5-8, M6-5, M6-8, M7-5, M7-8). Method 1: Distribution and generation
Sponsored link
immediate downloadReleased: 2017-07-10
BS EN 16798-5-1:2017 Energy performance of buildings. Ventilation for buildings Calculation methods for energy requirements of ventilation and air conditioning systems (Modules M5-6, M5-8, M6-5, M6-8, M7-5, M7-8). Method 1: Distribution and generation

BS EN 16798-5-1:2017

Energy performance of buildings. Ventilation for buildings Calculation methods for energy requirements of ventilation and air conditioning systems (Modules M5-6, M5-8, M6-5, M6-8, M7-5, M7-8). Method 1: Distribution and generation

Format
Availability
Price and currency
English Secure PDF
Immediate download
399.30 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
39.93 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
119.79 EUR
English Hardcopy
In stock
399.30 EUR
Standard number:BS EN 16798-5-1:2017
Pages:80
Released:2017-07-10
ISBN:978 0 580 86288 5
Status:Standard
DESCRIPTION

BS EN 16798-5-1:2017


This standard BS EN 16798-5-1:2017 Energy performance of buildings. Ventilation for buildings is classified in these ICS categories:
  • 91.120.10 Thermal insulation of buildings
  • 91.140.30 Ventilation and air-conditioning systems
This European Standard covers the energy performance calculation of mechanical ventilation and air conditioning systems, including humidification and dehumidification. It takes into account the generation (air handling unit) and distribution (duct system) parts. It includes a simplified calculation of adiabatic cooling systems. It does not cover the emission part (calculation of the required volume flow rates and/or supply air conditions), which is covered in EN 16798-7. It does not include the calculation of heating/cooling generation. This method is focussed on large customized ventilation and air conditioning systems, typically used in commercial buildings, although the application is not restricted on the basis of building or space use type. A calculation method for ventilation systems with integrated heating/cooling generation, including domestic hot water generation, using a monthly or seasonal calculation interval or a bin method, is provided in a separate standard, EN 16798-5-2. This method does not include humidification and dehumidification or adiabatic cooling. Table 1 shows the relative position of this standard within the set of EPB standards in the context of the modular structure as set out in EN ISO 52000 1. NOTE 1 In CEN ISO/TR 52000 2 the same table can be found, with, for each module, the numbers of the relevant EPB standards and accompanying technical reports that are published or in preparation. NOTE 2 The modules represent EPB standards, although one EPB standard might cover more than one module and one module might be covered by more than one EPB standard, for instance a simplified and a detailed method respectively. See also Clause 2 and Tables A.1 and B.1.