BS EN 17414-1:2020
District cooling pipes. Factory made flexible pipe system Classification, general requirements and test methods
Standard number: | BS EN 17414-1:2020 |
Pages: | 38 |
Released: | 2020-08-05 |
ISBN: | 978 0 539 04615 1 |
Status: | Standard |
BS EN 17414-1:2020 District Cooling Pipes
Factory Made Flexible Pipe System: Classification, General Requirements, and Test Methods
Introducing the BS EN 17414-1:2020, a comprehensive standard that sets the benchmark for district cooling pipes. This standard is essential for professionals in the field of district cooling systems, providing a detailed framework for the classification, general requirements, and test methods of factory-made flexible pipe systems. Released on August 5, 2020, this document is a crucial resource for ensuring the quality and reliability of cooling infrastructure.
Key Features of BS EN 17414-1:2020
The BS EN 17414-1:2020 standard is meticulously crafted to address the specific needs of district cooling systems. Here are some of the key features that make this standard indispensable:
- Comprehensive Classification: The standard provides a detailed classification system for district cooling pipes, ensuring that all components meet the necessary specifications for optimal performance.
- General Requirements: It outlines the essential requirements that all factory-made flexible pipe systems must adhere to, ensuring consistency and reliability across installations.
- Rigorous Test Methods: The standard includes a variety of test methods to verify the performance and durability of the pipe systems, ensuring they can withstand the demands of real-world applications.
Why Choose BS EN 17414-1:2020?
Choosing the BS EN 17414-1:2020 standard means opting for a document that is not only comprehensive but also up-to-date with the latest industry practices. Here are some reasons why this standard is a must-have:
- Industry Relevance: As a standard specifically tailored for district cooling systems, it addresses the unique challenges and requirements of this sector.
- Quality Assurance: By adhering to this standard, manufacturers and installers can ensure that their products and services meet the highest quality benchmarks.
- Enhanced Performance: The guidelines provided help in optimizing the performance of cooling systems, leading to increased efficiency and reduced operational costs.
Technical Specifications
The BS EN 17414-1:2020 standard is a detailed document spanning 38 pages, packed with essential information for professionals in the field. Here are some of the technical specifications:
- Standard Number: BS EN 17414-1:2020
- Pages: 38
- Release Date: August 5, 2020
- ISBN: 978 0 539 04615 1
- Status: Standard
Applications of BS EN 17414-1:2020
This standard is applicable in a variety of settings where district cooling systems are employed. Some of the key applications include:
- Urban Cooling Networks: Ideal for large-scale urban cooling projects, ensuring efficient and reliable distribution of cooling resources.
- Commercial Buildings: Ensures that commercial establishments maintain optimal cooling conditions, enhancing comfort and productivity.
- Industrial Facilities: Provides guidelines for cooling systems in industrial settings, where maintaining specific temperature conditions is critical.
Conclusion
The BS EN 17414-1:2020 standard is an invaluable resource for anyone involved in the design, installation, or maintenance of district cooling systems. Its comprehensive guidelines ensure that all aspects of flexible pipe systems are covered, from classification to testing. By adhering to this standard, professionals can guarantee the quality, efficiency, and reliability of their cooling systems, ultimately leading to enhanced performance and customer satisfaction.
Invest in the BS EN 17414-1:2020 standard today and ensure that your district cooling systems are built to the highest standards of quality and performance.
BS EN 17414-1:2020
This standard BS EN 17414-1:2020 District cooling pipes. Factory made flexible pipe system is classified in these ICS categories:
- 23.040.99 Other pipeline components
This document specifies requirements and test methods for factory made thermally insulated flexible pipe-in-pipe assemblies for directly buried district cooling distribution systems, comprising a service pipe and a casing of polyethylene. The pipe assembly can also include the following additional elements: measuring wires, spacers and diffusion barriers.
This document is intended to be used in conjunction with EN 17414?2 or EN 17414?3.
This document applies only to insulated pipe assemblies, for continuous operation with water at various temperatures (1 to 30) °C and a maximum operation pressure of 25 bar dependent on material specified.
The design is based on an expected service life with continuous operation of a minimum 50 years. For pipe systems with plastic service pipes, the respective temperature profiles are defined in EN 17414?2 and EN 17414?3.
For the transport of other liquids, for example potable water, additional requirements could be applicable.