PRICES include / exclude VAT
Homepage>BS Standards>13 ENVIRONMENT. HEALTH PROTECTION. SAFETY>13.220 Protection against fire>13.220.20 Fire protection>BS EN 17451:2024 Fixed firefighting systems. Automatic sprinkler systems. Design, assembly, installation and commissioning of pump sets
Sponsored link
immediate downloadReleased: 2024-12-19
BS EN 17451:2024 Fixed firefighting systems. Automatic sprinkler systems. Design, assembly, installation and commissioning of pump sets

BS EN 17451:2024

Fixed firefighting systems. Automatic sprinkler systems. Design, assembly, installation and commissioning of pump sets

Format
Availability
Price and currency
English Secure PDF
Immediate download
348.00 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
34.80 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
104.40 EUR
English Hardcopy
In stock
348.00 EUR
Standard number:BS EN 17451:2024
Pages:48
Released:2024-12-19
ISBN:978 0 539 22618 8
Status:Standard
BS EN 17451:2024 - Fixed Firefighting Systems

BS EN 17451:2024 - Fixed Firefighting Systems: Automatic Sprinkler Systems

Introducing the BS EN 17451:2024, the definitive standard for the design, assembly, installation, and commissioning of pump sets in automatic sprinkler systems. This comprehensive document is essential for professionals in the firefighting and safety industry, providing the latest guidelines and best practices to ensure the highest level of safety and efficiency in fixed firefighting systems.

Key Features

  • Standard Number: BS EN 17451:2024
  • Pages: 48
  • Release Date: December 19, 2024
  • ISBN: 978 0 539 22618 8
  • Status: Standard

Comprehensive Coverage

This standard provides a detailed framework for the entire lifecycle of pump sets in automatic sprinkler systems, from initial design to final commissioning. It ensures that all components are correctly specified, assembled, and installed to meet the rigorous demands of modern firefighting systems.

Design

The design section of the BS EN 17451:2024 standard offers in-depth guidance on selecting the appropriate pump sets for various types of sprinkler systems. It covers critical factors such as water supply, pressure requirements, and system compatibility, ensuring that your firefighting system is both effective and reliable.

Assembly

Proper assembly is crucial to the performance of any firefighting system. This standard outlines the best practices for assembling pump sets, including the use of high-quality materials and components, precise alignment, and secure connections. By following these guidelines, you can ensure that your system operates smoothly and efficiently.

Installation

Installation is a critical phase in the deployment of automatic sprinkler systems. The BS EN 17451:2024 standard provides step-by-step instructions for installing pump sets, ensuring that they are correctly positioned and integrated into the overall system. This section also addresses common installation challenges and offers solutions to overcome them.

Commissioning

Commissioning is the final step in bringing your firefighting system online. This standard includes detailed procedures for testing and verifying the performance of pump sets, ensuring that they meet all necessary safety and operational standards. By following these procedures, you can be confident that your system is ready to protect lives and property.

Why Choose BS EN 17451:2024?

The BS EN 17451:2024 standard is an invaluable resource for anyone involved in the design, assembly, installation, and commissioning of automatic sprinkler systems. It reflects the latest advancements in firefighting technology and incorporates feedback from industry experts to provide the most up-to-date and effective guidelines available.

Benefits

  • Enhanced Safety: By adhering to this standard, you can ensure that your firefighting system is designed and installed to the highest safety standards, reducing the risk of failure in an emergency.
  • Improved Efficiency: The guidelines provided in this standard help optimize the performance of your system, ensuring that it operates efficiently and effectively when needed.
  • Compliance: Meeting the requirements of the BS EN 17451:2024 standard ensures compliance with national and international regulations, providing peace of mind and legal protection.

Who Should Use This Standard?

The BS EN 17451:2024 standard is designed for a wide range of professionals, including:

  • Fire safety engineers
  • System designers
  • Installation contractors
  • Maintenance personnel
  • Regulatory authorities

Conclusion

In the ever-evolving field of fire safety, staying up-to-date with the latest standards is crucial. The BS EN 17451:2024 provides a comprehensive and authoritative guide to the design, assembly, installation, and commissioning of pump sets in automatic sprinkler systems. By following this standard, you can ensure that your firefighting systems are safe, efficient, and compliant with the latest regulations.

Invest in the safety and reliability of your firefighting systems with the BS EN 17451:2024 standard. Equip yourself with the knowledge and guidelines necessary to protect lives and property effectively.

DESCRIPTION

BS EN 17451:2024


This standard BS EN 17451:2024 Fixed firefighting systems. Automatic sprinkler systems. Design, assembly, installation and commissioning of pump sets is classified in these ICS categories:
  • 13.220.20 Fire protection
This document specifies design, assembly, installation and commissioning requirements for pump sets for use in sprinkler systems conforming to EN 12845:2015+A1:2019. Where applicable, this document can also be used for pump sets for other water based fixed firefighting systems.