PRICES include / exclude VAT
Homepage>BS Standards>13 ENVIRONMENT. HEALTH PROTECTION. SAFETY>13.320 Alarm and warning systems>BS EN 50131-2-6:2008 Alarm systems. Intrusion and hold-up systems Opening contacts (magnetic)
Sponsored link
immediate downloadReleased: 2014-05-31
BS EN 50131-2-6:2008 Alarm systems. Intrusion and hold-up systems Opening contacts (magnetic)

BS EN 50131-2-6:2008

Alarm systems. Intrusion and hold-up systems Opening contacts (magnetic)

Format
Availability
Price and currency
English Secure PDF
Immediate download
312.18 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
31.22 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
93.65 EUR
English Hardcopy
In stock
312.18 EUR
Standard number:BS EN 50131-2-6:2008
Pages:38
Released:2014-05-31
ISBN:978 0 580 83560 5
Status:Standard
DESCRIPTION

BS EN 50131-2-6:2008


This standard BS EN 50131-2-6:2008 Alarm systems. Intrusion and hold-up systems is classified in these ICS categories:
  • 13.320 Alarm and warning systems

This European Standard provides for security grades 1 to 4, (see EN 50131-1) specific or non-specific wired or wire-free opening contacts (magnetic), and includes the requirements for four environmental classes covering applications in internal and outdoor locations as specified in EN 50130-5.

A detector shall fulfil all the requirements of the specified grade.

Functions additional to the mandatory functions specified in this European Standard may be included in the detector, providing they do not influence the correct operation of the mandatory functions.

The two separate parts of the opening contact (magnetic) shall be referred to in the body of this European Standard as the detector.

This European Standard does not apply to system interconnections.