PRICES include / exclude VAT
Homepage>BS Standards>13 ENVIRONMENT. HEALTH PROTECTION. SAFETY>13.320 Alarm and warning systems>BS EN 50724:2023 Fixed Ultrasonic Gas Leak Detectors (UGLD). General requirements and test methods
Sponsored link
immediate downloadReleased: 2023-10-10
BS EN 50724:2023 Fixed Ultrasonic Gas Leak Detectors (UGLD). General requirements and test methods

BS EN 50724:2023

Fixed Ultrasonic Gas Leak Detectors (UGLD). General requirements and test methods

Format
Availability
Price and currency
English Secure PDF
Immediate download
292.80 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
29.28 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
87.84 EUR
English Hardcopy
In stock
292.80 EUR
Standard number:BS EN 50724:2023
Pages:34
Released:2023-10-10
ISBN:978 0 539 20239 7
Status:Standard

BS EN 50724:2023 Fixed Ultrasonic Gas Leak Detectors (UGLD). General requirements and test methods

Introducing the BS EN 50724:2023 Fixed Ultrasonic Gas Leak Detectors (UGLD), a comprehensive guide that sets the standard for the general requirements and test methods of fixed ultrasonic gas leak detectors. This standard is a must-have for professionals in the field, ensuring the highest level of safety and efficiency in the detection of gas leaks.

Released on October 10, 2023, this standard is the latest and most up-to-date guide in the industry. With a total of 34 pages, it provides a thorough and detailed overview of the requirements and testing methods for fixed ultrasonic gas leak detectors.

Key Features

The BS EN 50724:2023 standard is packed with essential information and guidelines that are crucial for the proper functioning and maintenance of fixed ultrasonic gas leak detectors. It includes:

  • General requirements for the design and construction of fixed ultrasonic gas leak detectors
  • Test methods to ensure the performance and reliability of the detectors
  • Guidelines for the installation, operation, and maintenance of the detectors

With its comprehensive content, this standard serves as a valuable resource for manufacturers, engineers, technicians, and other professionals involved in the design, production, installation, and maintenance of fixed ultrasonic gas leak detectors.

Why Choose BS EN 50724:2023?

The BS EN 50724:2023 standard is a product of rigorous research and development, ensuring that it provides the most accurate and reliable information. It is recognized and respected worldwide, making it a trusted reference in the industry.

By adhering to this standard, you can ensure that your fixed ultrasonic gas leak detectors meet the highest quality and safety standards. This not only protects your business from potential liabilities but also boosts your reputation in the market.

Get Your Copy Today

Order your copy of the BS EN 50724:2023 Fixed Ultrasonic Gas Leak Detectors (UGLD). General requirements and test methods today. With its ISBN number 978 0 539 20239 7, you can easily find and purchase it from reputable bookstores and online platforms.

Don't miss out on this essential guide. Equip yourself with the knowledge and skills to ensure the safety and efficiency of your fixed ultrasonic gas leak detectors. Get your copy of the BS EN 50724:2023 standard today!

Note: This standard is currently in effect. Please ensure to stay updated with the latest versions for the most accurate and reliable information.

DESCRIPTION

BS EN 50724:2023


This standard BS EN 50724:2023 Fixed Ultrasonic Gas Leak Detectors (UGLD). General requirements and test methods is classified in these ICS categories:
  • 13.320 Alarm and warning systems
This document refers to UGLDs (ultrasonic gas leak detectors) that work in a frequency beyond the audible range. This document is applicable to fixed ultrasonic gas leak detection equipment intended to provide an indication, alarm or other output function for the purpose of initiating automatic or manual protective action(s). This document specifies general requirements for design, testing and performance, and describes test methods that apply to UGLD. The following items are considered in this document: - Leak rates to be used to verify the detection range of UGLD, - Test gas to be used (nitrogen or compressed air), - Nozzle shape and size used at all tests leak rate tests, - Gas pressure used at all leak rate tests, - Time duration of each leak rate test, - Test leak nozzle height from solid ground, - Test leak nozzle angling relative to test UGLD, - UGLD angle relative to the leak (field of coverage of the UGLD), - Wind speed and direction, air temperature and humidity at day of test, - Minimum distance to solid structures (walls, etc.) at test site, - Installation height relative to the ground, - Texture of solid ground between leak and UGLD, - Background noise sources, known to interfere with UGLDs, - Specification of detection radius in 3 dimensions, - Operational requirements such as temperature, vibration, etc. This document is also applicable when an equipment manufacturer makes any claims regarding any special features of construction or superior performance that exceed the minimum requirements of this document. This document prescribes that all such claims are verified, and that the test procedures are extended or supplemented, where necessary, to verify the claimed performance. The additional tests are agreed between the manufacturer and test laboratory and identified and described in the test report. This document does not apply to portable gas detectors using ultrasonic measurements nor to gas detectors using non-ultrasonic measurements to detect a gas leak.