PRICES include / exclude VAT
Homepage>BS Standards>13 ENVIRONMENT. HEALTH PROTECTION. SAFETY>13.220 Protection against fire>13.220.40 Ignitability and burning behaviour of materials and products>BS EN 60332-1-2:2004+A12:2020 Tests on electric and optical fibre cables under fire conditions Test for vertical flame propagation for a single insulated wire or cable. Procedure for 1 kW pre-mixed flame
Sponsored link
immediate downloadReleased: 2020-12-15
BS EN 60332-1-2:2004+A12:2020 Tests on electric and optical fibre cables under fire conditions Test for vertical flame propagation for a single insulated wire or cable. Procedure for 1 kW pre-mixed flame

BS EN 60332-1-2:2004+A12:2020

Tests on electric and optical fibre cables under fire conditions Test for vertical flame propagation for a single insulated wire or cable. Procedure for 1 kW pre-mixed flame

Format
Availability
Price and currency
English Secure PDF
Immediate download
191.18 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
19.12 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
57.35 EUR
English Hardcopy
In stock
191.18 EUR
Standard number:BS EN 60332-1-2:2004+A12:2020
Pages:18
Released:2020-12-15
ISBN:978 0 539 13056 0
Status:Standard
BS EN 60332-1-2:2004+A12:2020 - Fire Test Standard

BS EN 60332-1-2:2004+A12:2020

Comprehensive Fire Safety Testing for Electric and Optical Fibre Cables

In the realm of electrical and optical fibre cable safety, the BS EN 60332-1-2:2004+A12:2020 standard stands as a critical benchmark. This standard outlines the rigorous testing procedures necessary to evaluate the vertical flame propagation characteristics of a single insulated wire or cable under fire conditions. With the increasing complexity and integration of electrical systems in modern infrastructure, ensuring the fire safety of cables is paramount. This standard provides a detailed methodology for conducting these essential tests.

Key Features of the Standard

  • Standard Number: BS EN 60332-1-2:2004+A12:2020
  • Pages: 18
  • Release Date: December 15, 2020
  • ISBN: 978 0 539 13056 0
  • Status: Standard

Purpose and Application

The primary purpose of this standard is to ensure that electric and optical fibre cables can withstand fire conditions without contributing to the spread of flames. This is particularly crucial in environments where cables are densely packed or where they run through critical infrastructure. The test outlined in this standard is designed to simulate real-world fire scenarios, providing a reliable measure of a cable's fire resistance.

Testing Procedure

The BS EN 60332-1-2:2004+A12:2020 standard specifies a procedure for testing the vertical flame propagation of a single insulated wire or cable using a 1 kW pre-mixed flame. This method is meticulously designed to assess the flame-retardant properties of cables, ensuring they meet the necessary safety requirements. The procedure involves exposing the cable to a controlled flame and observing its behavior, including the extent of flame spread and the duration of burning.

Importance of Compliance

Compliance with the BS EN 60332-1-2:2004+A12:2020 standard is essential for manufacturers and suppliers of electric and optical fibre cables. Adhering to this standard not only ensures the safety and reliability of the cables but also enhances their marketability. Products that meet these stringent safety criteria are more likely to be accepted in international markets, where safety regulations are becoming increasingly stringent.

Benefits of the Standard

Adopting the BS EN 60332-1-2:2004+A12:2020 standard offers numerous benefits, including:

  • Enhanced Safety: By ensuring that cables do not contribute to the spread of fire, this standard helps protect lives and property.
  • Regulatory Compliance: Meeting the requirements of this standard ensures compliance with national and international fire safety regulations.
  • Market Acceptance: Products that comply with this standard are more likely to be accepted in global markets, enhancing their commercial viability.
  • Reputation: Manufacturers that adhere to this standard demonstrate a commitment to safety and quality, enhancing their reputation in the industry.

Conclusion

The BS EN 60332-1-2:2004+A12:2020 standard is an indispensable tool for ensuring the fire safety of electric and optical fibre cables. By providing a comprehensive testing procedure, it helps manufacturers produce safer, more reliable products that meet the demands of modern infrastructure. Whether you are a manufacturer, supplier, or consumer, understanding and adhering to this standard is crucial for ensuring safety and compliance in today's complex electrical environments.

DESCRIPTION

BS EN 60332-1-2:2004+A12:2020


This standard BS EN 60332-1-2:2004+A12:2020 Tests on electric and optical fibre cables under fire conditions is classified in these ICS categories:
  • 13.220.40 Ignitability and burning behaviour of materials and products
  • 33.180.10 Fibres and cables
  • 29.060.20 Cables
  • 29.020 Electrical engineering in general

This part of IEC 60332 specifies the procedure for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions. The apparatus is given in IEC 60332-1-1.

NOTE 1 Testing to IEC 60332-1-2 may be performed simultaneously with that to IEC 60332-1-3 if required.

Recommended requirements for performance are given in Annex A.

IEC 60332-1-2 specifies the use of a 1 kW pre-mixed flame and is for general use, except that the procedure specified may not be suitable for the testing of small single insulated conductors or cables of less than 0,5 mm² total cross-section because the conductor melts before the test is completed, or for the testing of small optical fibre cables because the cable is broken before the test is completed. In these cases, the procedure given in IEC 60332-2-2 is recommended.

NOTE 2 Since the use of insulated conductor or cable which retards flame propagation and complies with the recommended requirements of this standard is not sufficient by itself to prevent propagation of fire under all conditions of installation, it is recommended that wherever the risk of propagation is high, for example in long vertical runs of bunches of cables, special installation precautions should also be taken. It cannot be assumed that because the sample of cable complies with the performance requirements recommended in this standard, that a bunch of cables will behave in a similar manner. (See IEC 60332-3 series.)


Customers who bought this item also bought
English Secure PDF
Immediate download
266.20 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
26.62 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
79.86 EUR
English Hardcopy
In stock
266.20 EUR
English Secure PDF
Immediate download
162.14 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
16.21 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
48.64 EUR
English Hardcopy
In stock
162.14 EUR
English Secure PDF
Immediate download
266.20 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
26.62 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
79.86 EUR
English Hardcopy
In stock
266.20 EUR
English Secure PDF
Immediate download
191.18 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
19.12 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
57.35 EUR
English Hardcopy
In stock
191.18 EUR