BS EN 60601-2-36:2015 Medical electrical equipment Particular requirements for the basic safety and essential performance of equipment for extracorporeally induced lithotripsy

BS EN 60601-2-36:2015

Medical electrical equipment Particular requirements for the basic safety and essential performance of equipment for extracorporeally induced lithotripsy

Format
Availability
Price and currency
English Secure PDF
Immediate download
266.20 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
26.62 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
79.86 EUR
English Hardcopy
In stock
266.20 EUR
Standard number:BS EN 60601-2-36:2015
Pages:28
Released:2015-06-30
ISBN:978 0 580 76697 8
Status:Standard
DESCRIPTION

BS EN 60601-2-36:2015


This standard BS EN 60601-2-36:2015 Medical electrical equipment is classified in these ICS categories:
  • 11.040.01 Medical equipment in general
  • 11.040.60 Therapy equipment
IEC 60601-2-36:2014 applies to basic safety and essential performance of equipment for extracorporeally induced lithotripsy including equipment for other medical applications of therapeutic extracorporeally induced focused pressure pulses. The applicability of this particular standard is limited to components directly involved in the lithotripsy treatment, such as, but not limited to, the generator of the pressure pulse, patient support device, and their interactions with imaging and monitoring devices. Other devices, such as patient treatment planning computers, X-ray and ultrasonic devices, are excluded from this standard, because they are treated in other applicable IEC standards. This particular standard does not apply to ultrasound physiotherapy equipment intended to be used for physiotherapy; abd to ultrasound equipment intended to be used for high intensity therapeutic ultrasound (HITU) and other therapy equipment as described in Annex AA. This second edition cancels and replaces the first edition of IEC 60601-2-36 published in 1997. This edition constitutes a technical revision to align structurally with IEC 60601-1:2005 and its Amendment1:2012.