PRICES include / exclude VAT
Homepage>BS Standards>11 HEALTH CARE TECHNOLOGY>11.040 Medical equipment>11.040.55 Diagnostic equipment>BS EN 61010-2-101:2017 Safety requirements for electrical equipment for measurement, control and laboratory use Particular requirements for in vitro diagnostic (IVD) medical equipment
Sponsored link
immediate downloadReleased: 2017-03-31
BS EN 61010-2-101:2017 Safety requirements for electrical equipment for measurement, control and laboratory use Particular requirements for in vitro diagnostic (IVD) medical equipment

BS EN 61010-2-101:2017

Safety requirements for electrical equipment for measurement, control and laboratory use Particular requirements for in vitro diagnostic (IVD) medical equipment

Format
Availability
Price and currency
English Secure PDF
Immediate download
249.60 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
24.96 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
74.88 EUR
English Hardcopy
In stock
249.60 EUR
Standard number:BS EN 61010-2-101:2017
Pages:28
Released:2017-03-31
ISBN:978 0 580 80361 1
Status:Standard
DESCRIPTION

BS EN 61010-2-101:2017


This standard BS EN 61010-2-101:2017 Safety requirements for electrical equipment for measurement, control and laboratory use is classified in these ICS categories:
  • 19.080 Electrical and electronic testing
  • 71.040.10 Chemical laboratories. Laboratory equipment
  • 11.040.55 Diagnostic equipment
IEC 61010-2-101:2015 is available as IEC 61010-2-101:2015 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 61010-2-101:2015 applies to equipment intended for in vitro diagnostic (IVD) medical purposes, including self-test IVD medical purposes. It has the status of a group safety function, as specified in IEC Guide 104. This standard has been prepared in close collaboration with Working Group CENELEC BTTF 88.1. This second edition cancels and replaces the first edition published in 2002. It constitutes a technical revision and includes the following significant changes from the first edition, as well as numerous other changes:
- excluded IEC 61010-2-081 (general laboratory equipment) from the scope. This separates IEC 61010-2-081 and IEC 61010-2-101 equipment;
- updated Biohazard and Lot symbols in Table 1 in Clause 5;
- added requirement for within expiration consumables and authorized representative details in Instructions for Use to Clause 5;
- added requirement for gas or liquid markings and ratings to Clause 5;
- added requirement to include OPERATOR instructions to deal with consumable or sample spills, jams or breakage inside equipment, disposal of hazardous waste, personal protection, RISK reduction procedures relating to flammable liquids, burns from surfaces, and loading and unloading of sample and reagents in Instructions for Use to Clause 5;
- added requirement for manufacturer to provide instructions on equipment transport, storage and removal from use to Clause 5;
- added normative reference ISO 18113-5 for instructions for use of self-test IVD medical equipment in Clause 5;
- added requirement for OPERATOR maintenance instructions to Clause 7;
- added requirements for sample zones and loading zones to Clause 7;
- excluded equipment whose size and weight make unintentional movement unlikely from drop test in Clause 8;
- added requirement for biohazard marking to Clause 13;
- added requirement for interlock systems containing electric/electronic or programmable components to Clause 15;
- added informative reference to Usability standard IEC 62366 to Clause 16;
- replaced Clause 17 with requirements of ISO 14971 for RISK assessment.
- Annex BB Instructions for use for self-testing IVD Medical Equipment deleted and a reference given to ISO 18113-5 in Clause 5.

This publication is to be read in conjunction with IEC 61010-1:2010.