PRICES include / exclude VAT
Homepage>BS Standards>29 ELECTRICAL ENGINEERING>29.160 Rotating machinery>29.160.01 Rotating machinery in general>BS EN IEC 60034-30-3:2024 Rotating electrical machines Efficiency classes of high voltage AC motors (IE-code)
Sponsored link
immediate downloadReleased: 2024-03-26
BS EN IEC 60034-30-3:2024 Rotating electrical machines Efficiency classes of high voltage AC motors (IE-code)

BS EN IEC 60034-30-3:2024

Rotating electrical machines Efficiency classes of high voltage AC motors (IE-code)

Format
Availability
Price and currency
English Secure PDF
Immediate download
249.60 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
24.96 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
74.88 EUR
English Hardcopy
In stock
249.60 EUR
Standard number:BS EN IEC 60034-30-3:2024
Pages:28
Released:2024-03-26
ISBN:978 0 539 13989 1
Status:Standard
BS EN IEC 60034-30-3:2024 - Rotating Electrical Machines Efficiency Classes of High Voltage AC Motors (IE-code)

BS EN IEC 60034-30-3:2024 - Rotating Electrical Machines Efficiency Classes of High Voltage AC Motors (IE-code)

Standard Number: BS EN IEC 60034-30-3:2024

Pages: 28

Released: 2024-03-26

ISBN: 978 0 539 13989 1

Status: Standard

Overview

Introducing the BS EN IEC 60034-30-3:2024, a comprehensive standard that sets the benchmark for the efficiency classes of high voltage AC motors. This essential document is a must-have for professionals in the electrical engineering and manufacturing industries, providing critical guidelines to ensure optimal performance and energy efficiency of rotating electrical machines.

Why Choose BS EN IEC 60034-30-3:2024?

In today's fast-paced industrial landscape, efficiency and sustainability are paramount. The BS EN IEC 60034-30-3:2024 standard is meticulously designed to help you achieve these goals. Here are some compelling reasons to integrate this standard into your operations:

  • Enhanced Efficiency: This standard categorizes high voltage AC motors into various efficiency classes, enabling you to select the most energy-efficient options for your applications.
  • Compliance and Certification: Adhering to this standard ensures that your products meet international efficiency requirements, facilitating smoother market entry and regulatory compliance.
  • Cost Savings: By optimizing motor efficiency, you can significantly reduce energy consumption and operational costs, leading to substantial long-term savings.
  • Environmental Impact: Improved efficiency translates to lower carbon emissions, contributing to your organization's sustainability goals and environmental responsibility.

Key Features

The BS EN IEC 60034-30-3:2024 standard is packed with valuable information and guidelines, including:

  • Detailed Efficiency Classes: Comprehensive classification of high voltage AC motors based on their efficiency levels, helping you make informed decisions.
  • Technical Specifications: In-depth technical details and parameters to ensure precise implementation and adherence to the standard.
  • Best Practices: Recommendations and best practices for optimizing motor performance and achieving maximum efficiency.
  • Global Relevance: Internationally recognized standard that aligns with global efficiency requirements, making it applicable across various regions and industries.

Who Should Use This Standard?

The BS EN IEC 60034-30-3:2024 standard is an invaluable resource for a wide range of professionals, including:

  • Electrical Engineers: Gain insights into the latest efficiency classifications and technical specifications for high voltage AC motors.
  • Manufacturers: Ensure your products meet international efficiency standards and enhance their marketability.
  • Energy Consultants: Provide clients with expert advice on optimizing motor efficiency and reducing energy consumption.
  • Regulatory Bodies: Establish and enforce efficiency standards to promote energy conservation and sustainability.

How to Implement the Standard

Implementing the BS EN IEC 60034-30-3:2024 standard is a straightforward process that involves:

  1. Acquiring the Standard: Obtain a copy of the standard to access the detailed guidelines and specifications.
  2. Reviewing the Content: Thoroughly review the standard to understand the efficiency classifications and technical requirements.
  3. Assessing Your Motors: Evaluate your existing high voltage AC motors to determine their current efficiency levels.
  4. Implementing Changes: Make necessary adjustments to your motors or manufacturing processes to align with the standard's efficiency classes.
  5. Monitoring and Compliance: Continuously monitor motor performance and ensure ongoing compliance with the standard.

Conclusion

The BS EN IEC 60034-30-3:2024 standard is an indispensable tool for anyone involved in the design, manufacturing, or maintenance of high voltage AC motors. By adhering to this standard, you can achieve superior efficiency, reduce operational costs, and contribute to a more sustainable future. Don't miss out on the opportunity to elevate your operations and stay ahead in the competitive industrial landscape.

Invest in the BS EN IEC 60034-30-3:2024 standard today and take the first step towards a more efficient and sustainable tomorrow.

DESCRIPTION

BS EN IEC 60034-30-3:2024


This standard BS EN IEC 60034-30-3:2024 Rotating electrical machines is classified in these ICS categories:
  • 29.160.01 Rotating machinery in general
  • 29.160.10 Components for rotating machines
  • 29.160.30 Motors
IEC 60034-30-3:2024 specifies efficiency classes for fixed-speed three-phase high-voltage cage induction motors in accordance with IEC 60034-1 that - have a rated voltage exceeding 1 000 V, but not exceeding 11 kV; - have a rated power from 200 kW to 2 000 kW; This document provides the global harmonization of energy-efficiency classes of three-phase cage induction motors with rated voltage above 1 000 V that are rated for direct online starting and fixed-speed operation at a 50 Hz or 60 Hz supply with sinusoidal voltage.