PRICES include / exclude VAT
Homepage>BS Standards>13 ENVIRONMENT. HEALTH PROTECTION. SAFETY>13.220 Protection against fire>13.220.40 Ignitability and burning behaviour of materials and products>BS EN IEC 60332-3-23:2018 - TC Tracked Changes. Tests on electric and optical fibre cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables. Category B
Sponsored link
immediate downloadReleased: 2020-02-25
BS EN IEC 60332-3-23:2018 - TC Tracked Changes. Tests on electric and optical fibre cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables. Category B

BS EN IEC 60332-3-23:2018 - TC

Tracked Changes. Tests on electric and optical fibre cables under fire conditions Test for vertical flame spread of vertically-mounted bunched wires or cables. Category B

Format
Availability
Price and currency
English Secure PDF
Immediate download
252.00 EUR
English Hardcopy
In stock
252.00 EUR
Standard number:BS EN IEC 60332-3-23:2018 - TC
Released:2020-02-25
ISBN:978 0 539 09325 4
Status:Tracked Changes
DESCRIPTION

BS EN IEC 60332-3-23:2018 - TC


This standard BS EN IEC 60332-3-23:2018 - TC Tracked Changes. Tests on electric and optical fibre cables under fire conditions is classified in these ICS categories:
  • 29.060.20 Cables
  • 33.180.10 Fibres and cables
  • 29.020 Electrical engineering in general
  • 13.220.40 Ignitability and burning behaviour of materials and products
  • 97.120 Automatic controls for household use
IEC 60332-3-23:2018 is now available as IEC 60332-3-23:2018 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 60332-3-23:2018 covers category B for methods of test for the assessment of vertical flame spread of vertically-mounted bunched wires or cables, electrical or optical, under defined conditions.
This document relates to cables installed on the test ladder to achieve a nominal total volume of non-metallic material of 3,5 l/m of test sample. The flame application time is 40 min. The method of mounting uses the front of the standard ladder. The category is intended for general use where medium volumes of non-metallic material are required to be evaluated. The test is intended for type approval testing. The requirements for the selection of cables for testing are given in Annex A. The flame spread is measured as the extent of damage of the cable sample. This procedure can be used to demonstrate the cable’s ability to limit flame spread. A recommended performance requirement is given in Annex B. This second edition cancels and replaces the first edition published in 2000 and Amendment 1:2008. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) adjustments have been made to the title, and elsewhere, to emphasise the standard is applicable to optical fibre cables as well as metallic conductor types;
b) details of the way in which cables are mounted on the ladder have been better defined in order to improve repeatability and reproducibility.
It has the status of a group safety publication in accordance with IEC Guide 104.