PRICES include / exclude VAT
Homepage>BS Standards>29 ELECTRICAL ENGINEERING>29.120 Electrical accessories>29.120.99 Other electrical accessories>BS EN IEC 60947-4-1:2019 Low-voltage switchgear and controlgear Contactors and motor-starters. Electromechanical contactors and motor-starters
Sponsored link
immediate downloadReleased: 2021-06-02
BS EN IEC 60947-4-1:2019 Low-voltage switchgear and controlgear Contactors and motor-starters. Electromechanical contactors and motor-starters

BS EN IEC 60947-4-1:2019

Low-voltage switchgear and controlgear Contactors and motor-starters. Electromechanical contactors and motor-starters

Format
Availability
Price and currency
English Secure PDF
Immediate download
376.80 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
37.68 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
113.04 EUR
English Hardcopy
In stock
376.80 EUR
Standard number:BS EN IEC 60947-4-1:2019
Pages:194
Released:2021-06-02
ISBN:978 0 539 17802 9
Status:Standard
DESCRIPTION

BS EN IEC 60947-4-1:2019


This standard BS EN IEC 60947-4-1:2019 Low-voltage switchgear and controlgear is classified in these ICS categories:
  • 29.130.20 Low voltage switchgear and controlgear
  • 29.120.99 Other electrical accessories

This part of IEC 60947 is applicable to the following equipment:

  • electromechanical contactors and starters including motor protective switching device (MPSD);

  • actuators of contactor relays;

  • contacts dedicated exclusively to the coil circuit of this contactor or this contactor relay;

  • dedicated accessories (e.g. dedicated wiring, dedicated latch accessory);

intended to be connected to distribution circuits, motors circuits and other load circuits, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC.

This document covers also the assessment procedure for electromechanical overload protection used in safety applications such as protecting a motor located in explosive atmosphere from the outside atmosphere: See Annex L.

This document does not apply to:

  • starters for DC motors 1;

    NOTE 1 The requirements for DC motor starters are under consideration for the next maintenance cycle.

  • auxiliary contacts of contactors and contacts of contactor relays. These are covered by IEC 60947-5-1;

  • starter used downstream to frequency drive1;

    NOTE 2 Additional requirements for starter used downstream to frequency drive are under consideration for the next maintenance cycle.

  • short-circuit protective device integrated within starters other than MPSDs. This is covered by IEC 60947-2 and IEC 60947-3;

  • the use of the product with additional measure within explosive atmospheres. These are given in IEC 60079 series;

  • embedded software design rules1;

  • cyber security aspects. These are covered by IEC 62443 series.

The objective of this document is to state:

  1. the characteristics of the equipment;

  2. the conditions applicable to the equipment with reference to:

    1. its operation and behaviour,

    2. its dielectric properties,

    3. its degree of protection,

    4. its construction including safety measures against electric shock, fire hazard and mechanical hazard;

  3. the tests intended for confirming that these conditions have been met, and the methods to be adopted for these tests;

  4. the information to be given with the equipment or in the manufacturer's literature.