PRICES include / exclude VAT
Homepage>BS Standards>29 ELECTRICAL ENGINEERING>29.140 Lamps and related equipment>29.140.50 Lighting installation systems>BS EN IEC 62386-202:2023 - TC Tracked Changes. Digital addressable lighting interface Particular requirements for control gear. Self-contained emergency lighting (device type 1)
Sponsored link
immediate downloadReleased: 2023-02-27
BS EN IEC 62386-202:2023 - TC Tracked Changes. Digital addressable lighting interface Particular requirements for control gear. Self-contained emergency lighting (device type 1)

BS EN IEC 62386-202:2023 - TC

Tracked Changes. Digital addressable lighting interface Particular requirements for control gear. Self-contained emergency lighting (device type 1)

Format
Availability
Price and currency
English Secure PDF
Immediate download
487.20 EUR
English Hardcopy
In stock
487.20 EUR
Standard number:BS EN IEC 62386-202:2023 - TC
Pages:234
Released:2023-02-27
ISBN:978 0 539 26060 1
Status:Tracked Changes
DESCRIPTION

BS EN IEC 62386-202:2023 - TC


This standard BS EN IEC 62386-202:2023 - TC Tracked Changes. Digital addressable lighting interface is classified in these ICS categories:
  • 29.140.50 Lighting installation systems
  • 29.140.99 Other standards related to lamps
IEC 62386-202:2022 is applicable to control gear for control by digital signals of electronic lighting equipment which is associated with self-contained emergency lighting as described in IEC 61347-2-7 with additional control interface for configuring emergency operation. This second edition cancels and replaces the first edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
  1. scope updated,
  2. hardwired switch operation can be disabled,
  3. installation inhibit feature added,
  4. memory bank added,
  5. modes of operation clarified, with some changes and additions,
  6. command added to enter extended emergency mode,
  7. command added to extend time in duration test mode.