BS EN IEC 63047:2021
Nuclear instrumentation. Data format for list mode digital data acquisition used in radiation detection and measurement
Standard number: | BS EN IEC 63047:2021 |
Pages: | 116 |
Released: | 2021-02-24 |
ISBN: | 978 0 539 17036 8 |
Status: | Standard |
BS EN IEC 63047:2021
This standard BS EN IEC 63047:2021 Nuclear instrumentation. Data format for list mode digital data acquisition used in radiation detection and measurement is classified in these ICS categories:
- 27.120.20 Nuclear power plants. Safety
- 27.120.01 Nuclear energy in general
This international standard specifies the format of binary list-mode data at the output of digital data acquisition devices used for the detection and measurement of radiation. Such data acquisition devices may employ digital signal processors (DSPs) and field-programmable gate arrays (FPGAs) in combination with memory and a communication interface with a computer.
This document is applicable to those data acquisition devices which are able to record and present interaction data of radiation in detectors on an event-per-event basis, with data stored in an output file or streamed to a remote computer. Such list-mode data typically contains timestamp and energy information, but may also contain digital signals or properties like rise time or sub-areas of signals computed by the DSP or FPGA from the signal samples.
It is not the scope of this document to specify the communication protocol between data acquisition hardware and the instrument drivers. Instead, it specifies a standard format for the presentation of data acquired by one or more acquisition devices, to the user or user application.
This document only specifies the binary formatting of data. The formatted data may be sent or stored as specified by other protocols. Also, commands to control data acquisition devices are not included in this document.
This document does not put requirements on encryption or authentication of data. However, data is canonically encoded in the format of this document, which allows the application of data security algorithms.
This document does not replace IEC 62755. This document provides optional mechanisms to include IEC 62755 formatted data into list-mode data.
This document does not apply to data acquisition devices used as instrumentation and control systems in nuclear power plants, nor other safety-critical applications. It is also not intended for medical applications.