BS EN ISO 10301:1997
Water quality. Determination of highly volatile halogenated hydrocarbons. Gas-chromatographic methods
Standard number: | BS EN ISO 10301:1997 |
Pages: | 40 |
Released: | 1997-07-15 |
ISBN: | 0 580 27541 8 |
Status: | Standard |
BS EN ISO 10301:1997
This standard BS EN ISO 10301:1997 Water quality. Determination of highly volatile halogenated hydrocarbons. Gas-chromatographic methods is classified in these ICS categories:
- 13.060.50 Examination of water for chemical substances
This International Standard specifies two methods for the determination of highly volatile halogenated hydrocarbons using gas chromatography.
Section 2 specifies a method for the determination by liquid/liquid extraction of highly volatile halogenated hydrocarbons in drinking water, ground water, swimming pool water, most rivers and lakes and many sewage and industrial effluents. Typical values of "quantification limits" are given in table 1.
Table 1
Typical values of "quantification limits" for some highly volatile halogenated hydrocarbons using liquid/liquid extraction
Compound | Quantification limits μ9/l |
---|---|
Dichloromethane | 50 |
Chloroform | 0,05 - 0,3 |
Carbon tetrachloride | o 0 1 p |
1,1-Dichloroethane | 1,0-5 |
1,2-Dichloroethane | 5-10 |
1,1,1-Trichloroethane | 0,02 - 0,1 |
1,1,2,2-T etrachloroethane | 0,05 - 0,1 |
Hexachloroethane | 0,01 - 0,05 |
cis-1,2-Dichloroethylene | 5-50 |
trans,2-Dichloroethylene | 1 - 10 |
Trichloroethylene | 0,05-0,1 |
Tetrachloroethylene | 0,1 |
Hexachlorobutadiene | 0,01 |
Tribromomethane | 0,1 |
1,1,2-Trichlorotrifluoroethane | 0,1 |
Section 3 specifies a method for the determination of highly volatile halogenated hydrocarbons in drinking water, surface waters and ground water by a static headspace method. Typical values of "quantification limits" are given in table 2.
In practise, the head-space method is applicable for industrial effluents as a screening method, but in some cases it is necessary to confirm the result by the liquid-liquid extraction method.
NOTE: When applying this International Standard, the guide on analytical quality control for water analysis (see ISO/TR 13530) should be followed, especially for the calibration steps.
Table 2
Typical values of "quantification limits" for some highly volatile halogenated hydrocarbons using static head-space method
Compound | Quantification limits μ9/I |
---|---|
Dichloromethane | 50 |
Chloroform | 0,3 |
Carbon tetrachloride | 0,1 |
1,1-Dichloroethane | 100 |
1,2-Dichloroethane | 100 |
1,1,1-Trichloroethane | 0,1 |
1,1,2-Trichloroethane | 20 |
1,1-Dichloroethylene | 10 |
cis-1,2-Dichloroethylene | 50 |
trans-1 ,2-Dichloroethylene | 25 |
Trichloroethylene | 0,2 |
Tetrachloroethylene | 0,2 |
1,2-Dichloropropane | 50 |
1,3-Dichloropropane | 200 |
cis+ trans-1,3-Dichloropropylene | 10 |
Dibromomethane | 0,3 |
Tribromomethane (Bromoform) | 5 |
1,2-Dibromoethane | 2 |
Bromochloromethane | 1 |
Bromodichloromethane | 0,2 |
Dibromochloromethane | 0,3 |