PRICES include / exclude VAT
Homepage>BS Standards>91 CONSTRUCTION MATERIALS AND BUILDING>91.120 Protection of and in buildings>91.120.20 Acoustics in building. Sound insulation>BS EN ISO 10848-4:2017 Acoustics. Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms Application to junctions with at least one Type A element
Sponsored link
immediate downloadReleased: 2017-11-24
BS EN ISO 10848-4:2017 Acoustics. Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms Application to junctions with at least one Type A element

BS EN ISO 10848-4:2017

Acoustics. Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms Application to junctions with at least one Type A element

Format
Availability
Price and currency
English Secure PDF
Immediate download
162.14 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
16.21 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
48.64 EUR
English Hardcopy
In stock
162.14 EUR
Standard number:BS EN ISO 10848-4:2017
Pages:14
Released:2017-11-24
ISBN:978 0 580 94766 7
Status:Standard
DESCRIPTION

BS EN ISO 10848-4:2017


This standard BS EN ISO 10848-4:2017 Acoustics. Laboratory and field measurement of flanking transmission for airborne, impact and building service equipment sound between adjoining rooms is classified in these ICS categories:
  • 91.120.20 Acoustics in building. Sound insulation

ISO 10848 (all parts) specifies measurement methods to characterize the flanking transmission of one or several building components.

This document specifies laboratory and field measurements of buildings where at least one of the elements that form the construction under test is a Type A element (defined in ISO 10848‑1 ).

Laboratory measurements are used to quantify the performance of the junction with suppressed flanking transmission from the laboratory structure. Field measurements are used to characterize the in situ performance and it is not usually possible to suppress unwanted flanking transmission sufficiently; hence, the results are primarily representative of the performance of that junction when installed in that particular building structure.

The measured quantities can be used to compare different products, or to express a requirement, or as input data for prediction methods, such as ISO 12354‑1 and ISO 12354‑2.