PRICES include / exclude VAT
Homepage>BS Standards>17 METROLOGY AND MEASUREMENT. PHYSICAL PHENOMENA>17.140 Acoustics and acoustic measurements>17.140.01 Acoustic measurements and noise abatement in general>BS EN ISO 3743-1:2010 Acoustics. Determination of sound power levels and sound energy levels of noise sources using sound pressure. Engineering methods for small movable sources in reverberant fields Comparison method for a hard-walled test room
Sponsored link
immediate downloadReleased: 2010-10-31
BS EN ISO 3743-1:2010 Acoustics. Determination of sound power levels and sound energy levels of noise sources using sound pressure. Engineering methods for small movable sources in reverberant fields Comparison method for a hard-walled test room

BS EN ISO 3743-1:2010

Acoustics. Determination of sound power levels and sound energy levels of noise sources using sound pressure. Engineering methods for small movable sources in reverberant fields Comparison method for a hard-walled test room

Format
Availability
Price and currency
English Secure PDF
Immediate download
331.20 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
33.12 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
99.36 EUR
English Hardcopy
In stock
331.20 EUR
Standard number:BS EN ISO 3743-1:2010
Pages:48
Released:2010-10-31
ISBN:978 0 580 53879 7
Status:Standard
DESCRIPTION

BS EN ISO 3743-1:2010


This standard BS EN ISO 3743-1:2010 Acoustics. Determination of sound power levels and sound energy levels of noise sources using sound pressure. Engineering methods for small movable sources in reverberant fields is classified in these ICS categories:
  • 17.140.01 Acoustic measurements and noise abatement in general

1.1 General

This part of ISO 3743 specifies methods for determining the sound power level or sound energy level of a noise source by comparing measured sound pressure levels emitted by this source (machinery or equipment) mounted in a hard-walled test room, the characteristics of which are specified, with those from a calibrated reference sound source. The sound power level (or, in the case of noise bursts or transient noise emission, the sound energy level) produced by the noise source, in frequency bands of width one octave, is calculated using those measurements. The sound power level or sound energy level with A-weighting applied is calculated using the octave-band levels.

1.2 Types of noise and noise sources

The method specified in this part of ISO 3743 is suitable for all types of noise (steady, non-steady, fluctuating, isolated bursts of sound energy, etc.) defined in ISO 12001.

The noise source under test may be a device, machine, component or sub-assembly. The maximum size of the source depends upon the size of the room used for the acoustical measurements (see 4.2).

1.3 Test environment

The test environment that is applicable for measurements made in accordance with this part of ISO 3743 is a hard-walled test room with prescribed acoustical characteristics.

1.4 Measurement uncertainty

Information is given on the uncertainty of the sound power levels and sound energy levels determined in accordance with this part of ISO 3743, for measurements made in frequency octave bands and for A-weighted frequency calculations performed on them. The uncertainty conforms to ISO 12001:1996, accuracy grade 2 (engineering grade).