PRICES include / exclude VAT
Homepage>BS Standards>17 METROLOGY AND MEASUREMENT. PHYSICAL PHENOMENA>17.120 Measurement of fluid flow>17.120.10 Flow in closed conduits>BS EN ISO 5167-6:2022 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Wedge meters
Sponsored link
immediate downloadReleased: 2022-11-07
BS EN ISO 5167-6:2022 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Wedge meters

BS EN ISO 5167-6:2022

Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Wedge meters

Format
Availability
Price and currency
English Secure PDF
Immediate download
191.18 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
19.12 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
57.35 EUR
English Hardcopy
In stock
191.18 EUR
Standard number:BS EN ISO 5167-6:2022
Pages:22
Released:2022-11-07
ISBN:978 0 539 19496 8
Status:Standard
BS EN ISO 5167-6:2022 - Measurement of Fluid Flow by Means of Pressure Differential Devices

BS EN ISO 5167-6:2022 - Measurement of Fluid Flow by Means of Pressure Differential Devices Inserted in Circular Cross-Section Conduits Running Full Wedge Meters

Standard Number: BS EN ISO 5167-6:2022

Pages: 22

Released: 2022-11-07

ISBN: 978 0 539 19496 8

Status: Standard

Overview

The BS EN ISO 5167-6:2022 standard is an essential document for professionals involved in the measurement of fluid flow using pressure differential devices. This standard specifically addresses the use of wedge meters in circular cross-section conduits running full. It provides comprehensive guidelines and methodologies to ensure accurate and reliable fluid flow measurements, making it an indispensable resource for engineers, technicians, and researchers in the field of fluid dynamics.

Key Features

  • Comprehensive Guidelines: The standard offers detailed instructions on the installation, operation, and maintenance of wedge meters, ensuring precise fluid flow measurements.
  • Accuracy and Reliability: By adhering to the methodologies outlined in this standard, users can achieve high levels of accuracy and reliability in their fluid flow measurements.
  • International Standard: As an ISO standard, it is recognized and accepted globally, facilitating international collaboration and standardization in fluid flow measurement practices.
  • Updated Information: Released on 2022-11-07, this standard includes the latest advancements and best practices in the field, ensuring users have access to the most current information.

Applications

The BS EN ISO 5167-6:2022 standard is applicable in various industries where accurate fluid flow measurement is critical. Some of the key applications include:

  • Oil and Gas Industry: Ensuring precise measurement of fluid flow in pipelines, which is crucial for operational efficiency and safety.
  • Water Treatment Plants: Monitoring and controlling the flow of water through treatment processes to ensure optimal performance.
  • Chemical Processing: Accurate flow measurement is essential for maintaining the correct proportions of chemicals in various processes.
  • Power Generation: Ensuring the efficient flow of fluids in cooling and heating systems, which is vital for the overall performance of power plants.

Technical Specifications

The BS EN ISO 5167-6:2022 standard provides detailed technical specifications for the use of wedge meters in fluid flow measurement. Some of the key specifications include:

  • Design and Construction: Guidelines on the design and construction of wedge meters to ensure they meet the required standards for accuracy and reliability.
  • Installation Requirements: Detailed instructions on the proper installation of wedge meters in circular cross-section conduits running full, including positioning and alignment.
  • Operational Parameters: Specifications on the operational parameters, such as pressure and temperature ranges, to ensure accurate measurements.
  • Maintenance and Calibration: Recommendations for the regular maintenance and calibration of wedge meters to maintain their accuracy and reliability over time.

Benefits

Adopting the BS EN ISO 5167-6:2022 standard offers numerous benefits, including:

  • Enhanced Accuracy: By following the guidelines and methodologies outlined in the standard, users can achieve highly accurate fluid flow measurements.
  • Improved Reliability: The standard ensures that wedge meters are installed and operated correctly, reducing the risk of measurement errors and improving overall reliability.
  • Global Recognition: As an ISO standard, it is recognized and accepted worldwide, facilitating international collaboration and standardization in fluid flow measurement practices.
  • Cost Efficiency: Accurate and reliable fluid flow measurements can help optimize processes, reduce waste, and improve operational efficiency, leading to cost savings.

Conclusion

The BS EN ISO 5167-6:2022 standard is a vital resource for professionals involved in the measurement of fluid flow using pressure differential devices. With its comprehensive guidelines, detailed technical specifications, and emphasis on accuracy and reliability, this standard ensures that users can achieve precise and dependable fluid flow measurements. Whether you are working in the oil and gas industry, water treatment, chemical processing, or power generation, the BS EN ISO 5167-6:2022 standard provides the essential information and best practices needed to optimize your fluid flow measurement processes.

DESCRIPTION

BS EN ISO 5167-6:2022


This standard BS EN ISO 5167-6:2022 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full is classified in these ICS categories:
  • 17.120.10 Flow in closed conduits
This document specifies the geometry and method of use (installation and operating conditions) of wedge meters when they are inserted in a conduit running full to determine the flow rate of the fluid flowing in the conduit. NOTE 1    As the uncertainty of an uncalibrated wedge meter can be too large for a particular application, it could be deemed essential to calibrate the flow meter according to Clause 7. This document gives requirements for calibration which, if applied, are for use over the calibrated Reynolds number range. Clause 7 could also be useful guidance for calibration of meters of similar design but which fall outside the scope of this document. It also provides background information for calculating the flow rate and is applicable in conjunction with the requirements given in ISO 5167?1. This document is applicable only to wedge meters in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase. Uncalibrated wedge meters can only be used within specified limits of pipe size, roughness, ? (or wedge ratio) and Reynolds number. It is not applicable to the measurement of pulsating flow. It does not cover the use of uncalibrated wedge meters in pipes whose internal diameter is less than 50 mm or more than 600 mm, or where the pipe Reynolds numbers are below 1 × 104. NOTE 2    A wedge meter has a primary element which consists of a wedge-shaped restriction of a specific geometry. Alternative designs of wedge meters are available; however, at the time of writing there is insufficient data to fully characterize these devices, and therefore these meters are calibrated in accordance with Clause 7.