PRICES include / exclude VAT
Homepage>BS Standards>13 ENVIRONMENT. HEALTH PROTECTION. SAFETY>13.220 Protection against fire>13.220.20 Fire protection>BS ISO 14186:2013 Air cargo. Fire containment covers. Design, performance and testing requirements
Sponsored link
immediate downloadReleased: 2013-08-31
BS ISO 14186:2013 Air cargo. Fire containment covers. Design, performance and testing requirements

BS ISO 14186:2013

Air cargo. Fire containment covers. Design, performance and testing requirements

Format
Availability
Price and currency
English Secure PDF
Immediate download
312.18 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
31.22 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
93.65 EUR
English Hardcopy
In stock
312.18 EUR
Standard number:BS ISO 14186:2013
Pages:38
Released:2013-08-31
ISBN:978 0 580 78088 2
Status:Standard
DESCRIPTION

BS ISO 14186:2013


This standard BS ISO 14186:2013 Air cargo. Fire containment covers. Design, performance and testing requirements is classified in these ICS categories:
  • 49.120 Cargo equipment
  • 13.220.20 Fire protection

1.1

This International Standard specifies the minimum design and performance criteria and testing methods of fire containment covers (FCCs) used:

  1. either in those cargo compartments of civil transport aircraft where they constitute one means of complying with applicable airworthiness regulations,

  2. or on a voluntary basis, when deemed appropriate by operators to improve fire protection in aircraft cargo compartments where airworthiness regulations do not mandate their use.

1.2

The FCCs specified by this International Standard are intended to be used to cover unitized cargo contained/restrained in an air cargo pallet and net assembly, for loading into aircraft main deck cargo compartments:

  1. either class F aircraft cargo compartments according to CS-25 § 25.857(f) and AMC to CS-25.855 and 25.857, in accordance with 1.1 a) above,

  2. or class B aircraft cargo compartments according to CS-25, CCAR-25, JAS Part 3 or 14 CFR Part 25 § 25.857 (b), in accordance with 1.1 a) or 1.1 b) above,

  3. or class E aircraft cargo compartments according to CS-25, CCAR-25, JAS Part 3 or 14 CFR Part 25 § 25.857 (e), in accordance with 1.1 b) above.

NOTE Though nothing prevents an FCC from being carried in a lower deck class C aircraft cargo compartment, it is not intended for this use since its fire containment capability would be redundant with that of the aircraft's fire detection and suppression system, which it could hamper.

1.3

The FCCs specified by this International Standard may be of two types:

  1. type I: separate devices to be installed over a pallet's load below a net approved for this purpose; or

  2. type II: devices permanently attached to a pallet net approved for this purpose.

1.4

The unit load devices (pallet and net) used in conjunction with the fire containment cover are specified in this International Standard only insofar as their flammability requirements are concerned. They are not otherwise specified in this International Standard.

NOTE See Bibliography for applicable ULD airworthiness approval and general design standards.

1.5

This International Standard is not intended to cover fire containment of loose baggage or loose cargo loaded in bulk cargo compartments.

1.6

This International Standard does not cover requirements for fire detection or suppression devices. The specified FCCs are passive devices.

1.7

The use of fire containment covers meeting the requirements of this International Standard is not sufficient alone to ensure flight safety: this International Standard is based on the assumption that the approved fire containment covers will be installed and checked prior to aircraft loading in accordance with appropriate operating instructions, by competent, suitably trained personnel as defined, for example, in ISO 9001:2008[9], 6.2.2 (see 9.3 hereafter).