PRICES include / exclude VAT
Homepage>BS Standards>13 ENVIRONMENT. HEALTH PROTECTION. SAFETY>13.040 Air quality>13.040.30 Workplace atmospheres>BS ISO 16200-1:2001 Workplace air quality. Sampling and analysis of volatile organic compounds by solvent desorption/gas chromatography Pumped sampling method
Sponsored link
immediate downloadReleased: 2004-11-26
BS ISO 16200-1:2001 Workplace air quality. Sampling and analysis of volatile organic compounds by solvent desorption/gas chromatography Pumped sampling method

BS ISO 16200-1:2001

Workplace air quality. Sampling and analysis of volatile organic compounds by solvent desorption/gas chromatography Pumped sampling method

Format
Availability
Price and currency
English Secure PDF
Immediate download
292.80 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
29.28 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
87.84 EUR
English Hardcopy
In stock
292.80 EUR
Standard number:BS ISO 16200-1:2001
Pages:34
Released:2004-11-26
ISBN:0 580 44878 9
Status:Standard
DESCRIPTION

BS ISO 16200-1:2001


This standard BS ISO 16200-1:2001 Workplace air quality. Sampling and analysis of volatile organic compounds by solvent desorption/gas chromatography is classified in these ICS categories:
  • 13.040.30 Workplace atmospheres

This part of ISO 16200 gives general guidance for the sampling and analysis of volatile organic compounds (VOCs) in air by solvent desorption/gas chromatography using pumped sampling.

This part of ISO 16200 is applicable to a wide range of VOCs, including hydrocarbons, halogenated hydrocarbons, esters, glycol ethers, ketones and alcohols. A number of sorbents are recommended for the sampling of these VOCs, each sorbent having a different range of applicability. However, activated coconut shell charcoal is frequently used. Very polar compounds may require derivatization; very low boiling compounds will only be partially retained by the sorbents and can only be estimated qualitatively. Semi-volatile compounds will be fully retained by the sorbents, but may only be partially recovered.

The upper limit of the useful range is set by the sorptive capacity of the sorbent used and by the linear dynamic range of the gas chromatograph column and detector or by the sample-splitting capability of the analytical instrumentation used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of analyte and/or interfering artefacts on the sorbent tubes or in the desorption solvent. Artefacts are typically subnanogram for activated charcoal, but higher levels of aromatic hydrocarbons have been noted in some batches.

The concentration range for which this part of ISO 16200 is valid for the measurement of airborne vapours of VOCs is dependent on the volume sampled. For example, for a 10-litre sample of air, the range is approximately 1 mg/m3 to 1000 mg/m3 individual organic compound. For a 1-litre sample of air, the range is approximately 10 mg/m3 to 10 000 mg/m3 individual organic compound, and pro rata.