PRICES include / exclude VAT
Homepage>BS Standards>91 CONSTRUCTION MATERIALS AND BUILDING>91.120 Protection of and in buildings>91.120.10 Thermal insulation>BS ISO 17772-1:2017 Energy performance of buildings. Indoor environmental quality Indoor environmental input parameters for the design and assessment of energy performance of buildings
immediate downloadReleased: 2017-07-07
BS ISO 17772-1:2017 Energy performance of buildings. Indoor environmental quality Indoor environmental input parameters for the design and assessment of energy performance of buildings

BS ISO 17772-1:2017

Energy performance of buildings. Indoor environmental quality Indoor environmental input parameters for the design and assessment of energy performance of buildings

Format
Availability
Price and currency
English Secure PDF
Immediate download
367.38 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
36.74 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
110.21 EUR
English Hardcopy
In stock
367.38 EUR
Standard number:BS ISO 17772-1:2017
Pages:74
Released:2017-07-07
ISBN:978 0 580 79056 0
Status:Standard
DESCRIPTION

BS ISO 17772-1:2017


This standard BS ISO 17772-1:2017 Energy performance of buildings. Indoor environmental quality is classified in these ICS categories:
  • 91.120.10 Thermal insulation of buildings

This document specifies requirements for indoor environmental parameters for thermal environment, indoor air quality, lighting and acoustics and specifies how to establish these parameters for building system design and energy performance calculations.

It includes design criteria for the local thermal discomfort factors, draught, radiant temperature asymmetry, vertical air temperature differences and floor surface temperature.

This document is applicable where the criteria for indoor environment are set by human occupancy and where the production or process does not have a major impact on indoor environment.

It also specifies occupancy schedules to be used in standard energy calculations and how different categories of criteria for the indoor environment can be used.

The criteria in this document can also be used in national calculation methods. This document sets criteria for the indoor environment based on existing standards and reports (listed in Clause 2 and the Bibliography).

The document does not specify design methods, but gives input parameters to the design of building envelope, heating, cooling, ventilation and lighting.