BS ISO 22248:2020
Lasers and laser-related equipment. Test methods for laser-induced damage threshold. Classification of medical beam delivery systems
Standard number: | BS ISO 22248:2020 |
Pages: | 28 |
Released: | 2020-11-17 |
ISBN: | 978 0 539 01183 8 |
Status: | Standard |
BS ISO 22248:2020 - Lasers and Laser-Related Equipment
Standard Number: BS ISO 22248:2020
Pages: 28
Released: 2020-11-17
ISBN: 978 0 539 01183 8
Status: Standard
Overview
The BS ISO 22248:2020 standard is an essential document for professionals working with lasers and laser-related equipment, particularly in the medical field. This standard provides comprehensive guidelines and test methods for determining the laser-induced damage threshold (LIDT) and classifying medical beam delivery systems. Released on November 17, 2020, this 28-page document is a critical resource for ensuring safety and efficacy in laser applications.
Key Features
- Comprehensive Test Methods: The standard outlines detailed procedures for assessing the laser-induced damage threshold, ensuring that equipment meets the necessary safety and performance criteria.
- Medical Beam Delivery Systems Classification: It provides a systematic approach to classifying medical beam delivery systems, facilitating better understanding and application in medical settings.
- Internationally Recognized: As an ISO standard, it is recognized globally, making it a valuable reference for international compliance and standardization.
Importance in the Medical Field
Lasers are increasingly used in medical procedures due to their precision and effectiveness. However, the potential for laser-induced damage necessitates stringent testing and classification to ensure patient safety and optimal outcomes. The BS ISO 22248:2020 standard plays a crucial role in this regard by providing a framework for evaluating and classifying laser systems used in medical applications.
Benefits of Compliance
Adhering to the BS ISO 22248:2020 standard offers numerous benefits, including:
- Enhanced Safety: By following the prescribed test methods, manufacturers and healthcare providers can minimize the risk of laser-induced damage, ensuring safer medical procedures.
- Improved Performance: The classification system helps in selecting the appropriate beam delivery systems, leading to better performance and outcomes in medical treatments.
- Regulatory Compliance: Compliance with this standard aids in meeting regulatory requirements, facilitating smoother market entry and acceptance.
Who Should Use This Standard?
This standard is indispensable for a wide range of professionals, including:
- Medical Device Manufacturers: To ensure their products meet international safety and performance standards.
- Healthcare Providers: To select and use laser equipment that complies with the latest safety guidelines.
- Regulatory Bodies: To establish and enforce safety standards for laser equipment in medical applications.
Conclusion
The BS ISO 22248:2020 standard is a vital resource for anyone involved in the design, manufacture, or use of laser and laser-related equipment in the medical field. By providing clear guidelines for testing and classification, it helps ensure that laser systems are safe, effective, and compliant with international standards. Whether you are a manufacturer, healthcare provider, or regulatory authority, this standard is an essential tool for achieving excellence in laser applications.
BS ISO 22248:2020
This standard BS ISO 22248:2020 Lasers and laser-related equipment. Test methods for laser-induced damage threshold. Classification of medical beam delivery systems is classified in these ICS categories:
- 31.260 Optoelectronics. Laser equipment
This document specifies a method of testing the laser-induced ignition and damage of medical beam delivery systems to allow checking of suitable products according to the classification system.
Take care when interpreting these results, since the direct applicability of the results of this test method to the clinical situation has not been fully established.
Users of products tested by this method are cautioned that the laser will be wavelength sensitive and tested at the wavelength for which it is intended to be used. If tested using other wavelengths, the power settings and modes of beam delivery need to be explicitly stated.
This test method can involve hazardous materials, operations and equipment. This document provides advice on minimizing some of the risks associated with its use but does not purport to address all such risks. It is the responsibility of the user of this document to establish appropriate safety and health practices and to determine the applicability of regulatory limitations prior to use.