BS ISO 8102-2:2021
Electrical requirements for lifts, escalators and moving walks Electromagnetic compatibility with regard to immunity
Standard number: | BS ISO 8102-2:2021 |
Pages: | 26 |
Released: | 2021-01-19 |
ISBN: | 978 0 580 51946 8 |
Status: | Standard |
BS ISO 8102-2:2021 - Elevate Your Standards with Unmatched Electromagnetic Compatibility
In the ever-evolving world of modern infrastructure, ensuring the seamless operation of lifts, escalators, and moving walks is paramount. Introducing the BS ISO 8102-2:2021, a comprehensive standard that sets the benchmark for electromagnetic compatibility with regard to immunity. This standard is an essential resource for engineers, architects, and facility managers who are committed to maintaining the highest levels of safety and efficiency in their vertical transportation systems.
Key Features of BS ISO 8102-2:2021
- Standard Number: BS ISO 8102-2:2021
- Pages: 26
- Release Date: January 19, 2021
- ISBN: 978 0 580 51946 8
- Status: Standard
This standard is meticulously crafted to address the electromagnetic compatibility (EMC) requirements specifically for lifts, escalators, and moving walks. It provides a robust framework to ensure that these systems are immune to electromagnetic disturbances, which can otherwise lead to malfunctions or safety hazards.
Why Electromagnetic Compatibility Matters
In today's technologically advanced environments, electromagnetic interference (EMI) is a common challenge. It can originate from various sources such as mobile phones, radio transmitters, and other electronic devices. For lifts, escalators, and moving walks, EMI can disrupt normal operations, leading to potential safety risks and operational inefficiencies.
The BS ISO 8102-2:2021 standard is designed to mitigate these risks by establishing stringent EMC requirements. By adhering to this standard, you can ensure that your vertical transportation systems are resilient against electromagnetic disturbances, thereby enhancing their reliability and safety.
Comprehensive Coverage
Spanning 26 pages, this standard provides detailed guidelines and specifications that cover a wide range of scenarios and conditions. It is an indispensable tool for professionals involved in the design, installation, and maintenance of lifts, escalators, and moving walks. The standard's comprehensive approach ensures that all potential electromagnetic challenges are addressed, providing peace of mind to both operators and users.
Benefits of Implementing BS ISO 8102-2:2021
- Enhanced Safety: By ensuring electromagnetic immunity, the standard helps prevent unexpected malfunctions that could compromise user safety.
- Operational Efficiency: Minimize downtime and maintenance costs by reducing the likelihood of electromagnetic interference-related issues.
- Regulatory Compliance: Stay ahead of industry regulations and standards, demonstrating your commitment to quality and safety.
- Future-Proofing: As technology continues to advance, having a robust EMC framework in place ensures your systems remain compatible with new devices and technologies.
Who Should Use This Standard?
The BS ISO 8102-2:2021 is ideal for a wide range of professionals, including:
- Engineers: Design and implement systems that meet the highest EMC standards.
- Architects: Integrate compliant vertical transportation solutions into building designs.
- Facility Managers: Ensure ongoing compliance and operational efficiency of existing systems.
- Safety Inspectors: Evaluate and certify systems based on established EMC criteria.
Conclusion
Incorporating the BS ISO 8102-2:2021 standard into your projects is a proactive step towards ensuring the safety, reliability, and efficiency of lifts, escalators, and moving walks. With its detailed guidelines and comprehensive coverage, this standard is an invaluable resource for anyone involved in the vertical transportation industry. Elevate your standards and embrace the future of electromagnetic compatibility with BS ISO 8102-2:2021.
BS ISO 8102-2:2021
This standard BS ISO 8102-2:2021 Electrical requirements for lifts, escalators and moving walks is classified in these ICS categories:
- 91.140.90 Lifts. Escalators
This document specifies the immunity performance criteria and test levels for apparatus used in lifts, escalators and moving walks which are intended to be permanently installed in buildings including the basic safety requirements in regard to their electromagnetic environment. These levels represent essential EMC requirements.
This document refers to EM conditions as existing in residential, office and industrial buildings.
This document addresses commonly known EMC related hazards and hazardous situations relevant to lifts, escalators and moving walks when they are used as intended and under the conditions foreseen by the lift installer or escalator and/or moving walk manufacturer.
It is assumed that no ports connected to safety circuit only are rated at currents greater than 100 amps.
It is assumed that mobile telephones and radio transmitters used at frequencies and power of that stated in Table 1 are not placed within 200 mm distance from safety circuit(s).
However:
-
performance criteria and test levels for apparatus/assembly of apparatus used in general function circuits do not cover situations with an extremely low probability of occurrence;
-
this document does not apply to other apparatus already proven to be in conformity to the EMC national regulation, and not related to the safety of the lift, escalator or moving walk, such as lighting apparatus, communication apparatus, etc.
This document does not apply to electromagnetic environments such as:
-
radio transmitter stations;
-
railways and metros;
-
heavy industrial plant;
-
electricity power stations;
which need additional investigations.
This document is not applicable to apparatus which were manufactured before the date of its publication.