PRICES include / exclude VAT
Homepage>CSN Standards>83 ENVIRONMENT PROTECTION, WORKING AND PERSONAL PROTECTION, SAFETY OF MACHINE EQUIPMENT AND ERGONOMICS>8368 Sludge, treated biowaste and soil>CSN EN 16190 - Soil, treated biowaste and sludge - Determination of dioxins and furans and dioxin-like polychlorinated biphenyls by gas chromatography with high resolution mass selective detection (HR GC-MS)
Sponsored link
Released: 01.07.2019
CSN EN 16190 - Soil, treated biowaste and sludge - Determination of dioxins and furans and dioxin-like polychlorinated biphenyls by gas chromatography with high resolution mass selective detection (HR GC-MS)

CSN EN 16190

Soil, treated biowaste and sludge - Determination of dioxins and furans and dioxin-like polychlorinated biphenyls by gas chromatography with high resolution mass selective detection (HR GC-MS)

Format
Availability
Price and currency
English Hardcopy
In stock
92.00 EUR
FREE Shipping
Number of Standard:CSN EN 16190
Category:836806
Pages:52
Released:01.07.2019
Catalog number:507727
DESCRIPTION

CSN EN 16190

CSN EN 16190 This document specifies a method for quantitative determination of 17 2,3,7,8-chlorine substituted dibenzo-p-dioxins and dibenzofurans and dioxin-like polychlorinated biphenyls in sludge, treated biowaste and soil using liquid column chromatographic clean-up methods and GC/HRMS. The analytes to be determined with this document are listed in Table 1. Table 1 - Analytes and their abbreviations Substance Abbreviation Tetrachlorodibenzo-p-dioxin TCDD Pentachlorodibenzo-p-dioxin PeCDD Hexachlorodibenzo-p-dioxin HxCDD Heptachlorodibenzo-p-dioxin HpCDD Octachlorodibenzo-p-dioxin OCDD Tetrachlorodibenzofuran TCDF Pentachlorodibenzofuran PeCDF Hexachlorodibenzofuran HxCDF Heptachlorodibenzofuran HpCDF Octachlorodibenzofuran OCDF Polychlorinated biphenyl PCB Trichlorobiphenyl TCB Tetrachlorobiphenyl TeCB Pentachlorobiphenyl PeCB Hexachlorobiphenyl HxCB Heptachlorobiphenyl HpCB Decachlorobiphenyl DecaCB The limit of detection depends on the kind of sample, the congener, the equipment used and the quality of chemicals used for extraction and clean-up. Under the conditions specified in this document, limits of detection better than 1 ng/kg (expressed as dry matter) can be achieved. This method is "performance based". It is allowed to modify the method if all performance criteria given in this method are met.
Original English text of CSN EN Standard.
The price of the Standard included all amendments and correcturs.