PRICES include / exclude VAT
Homepage>CSN Standards>36 ELECTRICAL ENGINEERING>3648 Electrical medical instruments>CSN EN IEC 60601-2-1 ed. 3 - Medical electrical equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV
Sponsored link
Released: 01.09.2021
CSN EN IEC 60601-2-1 ed. 3 - Medical electrical equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV

CSN EN IEC 60601-2-1 ed. 3

Medical electrical equipment - Part 2-1: Particular requirements for the basic safety and essential performance of electron accelerators in the range 1 MeV to 50 MeV

Format
Availability
Price and currency
English Hardcopy
In stock
130.00 EUR
FREE Shipping
Number of Standard:CSN EN IEC 60601-2-1 ed. 3
Category:364801
Pages:124
Released:01.09.2021
Catalog number:512563
DESCRIPTION

CSN EN IEC 60601-2-1 ed. 3

CSN EN IEC 60601-2-1 ed. 3 This part of IEC 60601 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of ELECTRON ACCELERATORS, hereafter referred to as ME EQUIPMENT, in the range 1 MeV to 50 MeV, used for TREATMENT of PATIENTS. This particular standard, with the inclusion of TYPE TESTS and SITE TESTS, applies to the manufacture and some installation aspects of ELECTRON ACCELERATORS and their included equipment used to increase the precision, accuracy and volumetric targeting of the TREATMENT delivery intended for RADIOTHERAPY in medical practice, including those in which the selection and DISPLAY of TREATMENT PARAMETERS can be controlled automatically by PROGRAMMABLE ELECTRONIC SUBSYSTEMS (PESS), that, under NORMAL CONDITIONS and in NORMAL USE, deliver a RADIATION BEAM of X-RADIATION or ELECTRON RADIATION having - NOMINAL ENERGY in the range 1 MeV to 50 MeV, - maximum ABSORBED DOSE RATES between 0,001 Gy × s-1 and 1 Gy × s-1 at the ERP from the RADIATION SOURCE, and - REFERENCE TREATMENT DISTANCES (RTDs) between 0,5 m and 2 m from the RADIATION SOURCE; and intended to be - for NORMAL USE, operated under the authority of the RESPONSIBLE ORGANIZATION by QUALIFIED PERSONS appropriately licensed or having the required skills for a particular medical application, for particular SPECIFIED clinical purposes, - maintained in accordance with the recommendations given in the INSTRUCTIONS FOR USE, AND - subject to regular QUALITY ASSURANCE performance and calibration checks by a QUALIFIED PERSON.
Original English text of CSN EN Standard.
The price of the Standard included all amendments and correcturs.