PRICES include / exclude VAT
Homepage>BS Standards>13 ENVIRONMENT. HEALTH PROTECTION. SAFETY>13.040 Air quality>13.040.20 Ambient atmospheres>DD CEN/TS 16115-1:2011 Ambient air quality. Measurement of bioaerosols Determination of moulds using filter sampling systems and culture-based analyses
Sponsored link
immediate downloadReleased: 2011-05-31
DD CEN/TS 16115-1:2011 Ambient air quality. Measurement of bioaerosols Determination of moulds using filter sampling systems and culture-based analyses

DD CEN/TS 16115-1:2011

Ambient air quality. Measurement of bioaerosols Determination of moulds using filter sampling systems and culture-based analyses

Format
Availability
Price and currency
English Secure PDF
Immediate download
350.90 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
35.09 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
105.27 EUR
English Hardcopy
In stock
350.90 EUR
Standard number:DD CEN/TS 16115-1:2011
Pages:50
Released:2011-05-31
ISBN:978 0 580 71038 4
Status:Standard
DESCRIPTION

DD CEN/TS 16115-1:2011


This standard DD CEN/TS 16115-1:2011 Ambient air quality. Measurement of bioaerosols is classified in these ICS categories:
  • 13.040.20 Ambient atmospheres
This Technical Specification describes the measurement of moulds in ambient air in order to identify, quantify and characterize bioaerosol pollution in ambient air resulting from emissions from different sources. The method described specifies the sampling of moulds as part of the suspended particulate matter (SPM, here particles with aerodynamic diameter up to ca. 30 µm) using a filter sampling system with gelatine/poly-carbonate filter combination followed by the culture-based analyses on DG18 agar. The sampling duration can be varied between 10 min to 24 h. The health effect of bioaerosols is not limited to any particle fraction, therefore, this document describes the sampling of moulds as part of the suspended particulate matter as a convention method. NOTE The sampling method described in this document in principle is likely to be appropriate for the sampling of actinomycetes and other spore-forming bacteria (resistant to desiccation). For these species a special analytical procedure using different culture media should be applied, but this is not within the scope of this document. The standard method set out in this Technical Specification is accepted by convention as reference method. The measured quantity, here the number of colony forming units per cubic meter (CFU/m3), is determined by the inlet design of the sampling head, the associated operational parameters and the analytical procedure. Standardized methods for sampling, detection and enumeration of moulds including standards for sampling strategies are important for comparative assessment of moulds in ambient air. Before doing any measurements a plan for the measurement strategy is necessary (see CEN/TS 16115-2 [5]). WARNING - The use of this Technical Specification may involve hazardous materials, operations and equipment. This Technical Specification does not purport to address all the safety problems associated with its use. (...)