PRICES include / exclude VAT
Homepage>BS Standards>13 ENVIRONMENT. HEALTH PROTECTION. SAFETY>13.340 Protective equipment>13.340.20 Head protective equipment>DD ISO/TS 4869-5:2006 Acoustics. Hearing protectors Method for estimation of noise reduction using fitting by inexperienced test subjects
Sponsored link
immediate downloadReleased: 2006-12-29
DD ISO/TS 4869-5:2006 Acoustics. Hearing protectors Method for estimation of noise reduction using fitting by inexperienced test subjects

DD ISO/TS 4869-5:2006

Acoustics. Hearing protectors Method for estimation of noise reduction using fitting by inexperienced test subjects

Format
Availability
Price and currency
English Secure PDF
Immediate download
249.60 EUR
You can read the standard for 1 hour. More information in the category: E-reading
Reading the standard
for 1 hour
24.96 EUR
You can read the standard for 24 hours. More information in the category: E-reading
Reading the standard
for 24 hours
74.88 EUR
English Hardcopy
In stock
249.60 EUR
Standard number:DD ISO/TS 4869-5:2006
Pages:30
Released:2006-12-29
ISBN:0 580 49881 6
Status:Standard
DESCRIPTION

DD ISO/TS 4869-5:2006


This standard DD ISO/TS 4869-5:2006 Acoustics. Hearing protectors is classified in these ICS categories:
  • 13.340.20 Head protective equipment

This Technical Specification specifies a method for measuring noise reduction of passive hearing protectors at the threshold of hearing. The method is designed to provide estimates of the noise reduction obtained by typical groups of users in real-world occupational settings, who may lack the training and motivation to wear hearing protectors in an optimum manner.

The principle of the test method is to measure the difference in hearing threshold with and without wearing a hearing protector. This difference between the thresholds constitutes the noise reduction. The measurement is done twice on a given number of test subjects.

NOTE 1 The principle of measuring the influence of a hearing protector on the hearing threshold is used in ISO 4869-1 and in this Technical Specification. The method described in ISO 4869-1 yields the sound attenuation of the hearing protector under test. The result of the measurement is a pure physical characteristic of the hearing protector. The method described in this Technical Specification yields the performance of the system as a whole, i.e. the influence of hearing protector, test subjects, fitting and instruction.

This test method yields data that are collected at low sound pressure levels (close to the threshold of hearing), but which are also representative of the noise reduction values of hearing protectors at higher sound pressure levels. This Technical Specification is inapplicable for level-dependent hearing protectors for sound pressure levels above the point at which their level-dependent characteristics become effective.

NOTE 2 At frequencies below 500 Hz, real-ear noise reduction data measured according to this Technical Specification may be spuriously high by a few decibels, with the error increasing as the frequency decreases. The error results from masking of the occluded-ear threshold by physiological noise during testing.