PRICES include / exclude VAT
Homepage>IEEE Standards>29 ELECTRICAL ENGINEERING>29.220 Galvanic cells and batteries>29.220.10 Primary cells and batteries>IEEE 1013-2019 - IEEE Recommended Practice for Sizing Lead-Acid Batteries for Stand-Alone Photovoltaic (PV) Systems
Sponsored link
Released: 20.09.2019

IEEE 1013-2019 - IEEE Recommended Practice for Sizing Lead-Acid Batteries for Stand-Alone Photovoltaic (PV) Systems

IEEE Recommended Practice for Sizing Lead-Acid Batteries for Stand-Alone Photovoltaic (PV) Systems

Format
Availability
Price and currency
English PDF Redline
Immediate download
91.95 EUR
English PDF
Immediate download
67.36 EUR
English Hardcopy
In stock
84.47 EUR
Standard number:IEEE 1013-2019
Released:20.09.2019
ISBN:978-1-5044-5894-8
Pages:50
Status:Active
Language:English
DESCRIPTION

IEEE 1013-2019

This recommended practice describes a method for sizing both vented and valve-regulated lead-acid batteries in stand-alone PV systems. Installation, maintenance, safety, testing procedures, and consideration of battery types other than lead-acid are beyond the scope of this recommended practice. Sizing batteries for hybrid and grid-connected PV systems is beyond the scope of this recommended practice. Recommended practices for the remainder of the electrical systems associated with stand-alone PV installations are also beyond the scope of this recommended practice. Sizing examples are given for various representative system applications. Iterative techniques to optimize battery costs, which include consideration of the interrelationship between battery size, PV array size, and weather, are beyond the scope of this recommended practice.

This recommended practice is meant to assist system designers in sizing lead-acid batteries for residential, commercial, and industrial stand-alone PV systems.

Revision Standard - Active. A method for determining the energy-capacity requirements (sizing) of both vented and valve-regulated lead-acid batteries used in terrestrial stand-alone photovoltaic (PV) systems is described in this recommended practice. Sizing batteries for hybrid or grid-connected PV systems is beyond the scope of this recommended practice. Installation, maintenance, safety, testing procedures, and consideration of battery types other than lead-acid are beyond the scope of this recommended practice. Recommended practices for the remainder of the electrical systems associated with PV installations are also beyond the scope of this recommended practice.